ABB CP415 Скачать руководство пользователя страница 13

Dip Switches

ABB, 1SBC159107M020

1

13

4

Dip Switches

Dip switch

Function

SW1

Reserved

SW2

Reserved

SW3

 

SW4

Operation Mode

ON

ON

Runs user application

ON

OFF

Runs burn-in test program

OFF

ON

Updates BIOS

OFF

OFF

Runs bench test program

SW5

Communication Parameters

ON

The operator terminal uses the communication parameters 
defined on the operator terminal’s configuration screen for 
controller communication. 

OFF

The operator terminal uses the communication parameters 
defined in CP400Soft for controller communication. 

SW6

Password

ON

The operator terminal asks the operator to enter a password 
after power-on self-test.

OFF

No password is required to start the operator terminal.

SW7

System Menu

ON

The operator terminal displays the system menu. 

OFF

The operator terminal runs user application without displaying 
the system menu. 

SW8

Default User Level

ON

The default user level is set to 1 if the operator terminal 
requires no password to start its operation.

OFF

The default user level is set to 9 if the operator terminal 
requires no password to start its operation.

SW9

COM1 Port 

ON

For RS485, this switch has to be set ON. 

OFF

For RS422, this switch has to be set OFF. 

SW10

Reserved

Содержание CP415

Страница 1: ...CP415 Installation and Operation Manual ABB 1SBC159107M0201 2008 09 English Cover_MAEN958 fm Page 1 Friday August 29 2008 1 10 PM ...

Страница 2: ...1 Please read the entire installation manual prior to installing and using this equipment Only qualified personnel may install operate or repair this equipment ABB is not responsible for modified altered or renovated equipment Because the equipment has a wide range of applications users must acquire the appropriate knowledge to use the equipment properly in their specific applications Only parts a...

Страница 3: ...ns 10 3 3 Mounting Procedure 11 3 4 Grounding 11 3 5 Power Supply and Wiring 12 4 Dip Switches 13 5 Communication Ports 14 6 Operation 15 6 1 Self Test 15 6 2 System Menu 16 6 3 Bench and Function Tests 17 6 4 Setting Communication Parameters 17 6 5 Touch Screen Calibration 18 6 6 Downloading an Application 19 6 7 Uploading an Application 20 6 8 Copying an Application 21 6 9 Passwords 22 ...

Страница 4: ...Contents ABB 1SBC159107M0201 ...

Страница 5: ...s the requirements of article 4 of EMC directive 2004 108 EC Storing the operator terminal where the temperature is lower higher than recommended in this manual can cause the LCD display liquid to congeal become isotopic The LCD display liquid contains a powerful irritant In case of skin contact wash immediately with plenty of water In case of eye contact hold the eye open flush with plenty of wat...

Страница 6: ... must be separated from power cables for operational circuits Only use shielded cables to avoid unpredictable problems During Use Emergency stop and other safety functions may not be controlled from the operator terminal Do not use too much force or sharp objects when touching the keys display etc Service and Maintenance Only qualified personnel should carry out repairs The agreed warranty applies...

Страница 7: ...1 7 2 Installation 2 1 Package Contents The following parts are found in the box Operator terminal CP415 4 installation fasteners Power connector connected to the 24 V DC power input Installation and operation manual 1SBC159107M0201 ...

Страница 8: ...argeable lithium battery Display Mono STN LCD 16 shades of gray 240 x 240 pixels LED backlight lifetime approximately 30 000 h at 25 C Active area of display W x H 58 5 x 58 5 mm 30 x 30 characters of 8 x 8 size can be displayed Display adjustment Via touch screen Touch screen Analog Power supply 24 V DC 15 Less than 4 W Ambient temperature 0 to 50 C Storage temperature 10 to 60 C Ambient humidity...

Страница 9: ...Product Specifications ABB 1SBC159107M0201 9 3 1 Description of Parts Front Back Fixture Power lamp Communication lamp Display mounting holes DIP switches 1 10 COM1 RS232 RS422 RS485 DC power input ...

Страница 10: ...Product Specifications 10 ABB 1SBC159107M0201 3 2 External and Cut out Dimensions Unit mm Cutout dimension ...

Страница 11: ...e unit and fasten the screws into the front panel Do not tighten the screws with too much or uneven force or it may cause the deformation of the operator terminal 3 The operator terminal is to be installed within the angle of 0 to 135 as shown below 3 4 Grounding To make sure that the operator terminal works properly and to prevent it from radiating radio frequency noise it must be connected to th...

Страница 12: ...to the power connector and then turn the screws tight 3 Plug in the connector to the power input of the operator terminal Use copper conductors only 60 75 C Warning To avoid an electrical shock be sure to switch off the power before connecting the communication download cable to the operator terminal Note The power connector is already plugged into the power input of operator terminal when the pac...

Страница 13: ...for controller communication SW6 Password ON The operator terminal asks the operator to enter a password after power on self test OFF No password is required to start the operator terminal SW7 System Menu ON The operator terminal displays the system menu OFF The operator terminal runs user application without displaying the system menu SW8 Default User Level ON The default user level is set to 1 i...

Страница 14: ...er via RS232 RS422 or RS485 Only COM1 can be used for download Note Make sure that the connection is in accordance with the setting of the dip switches for example RS485 corresponds to SW9 ON See section 4 Dip Switches Pin Function 1 RS422 TX RS485 2 RS232 RXD 3 RS232 TXD 4 RS422 RX 5 Signal ground 6 RS422 TX RS485 7 RS232 RTS 8 RS232 CTS 9 RS422 RX ...

Страница 15: ...m or Application checksum will not pass the self test in dicated by Failed in the self test results after power is restored If this happens the user can simply follow the download procedure to re download the applica tion or data After downloading again all items should pass the self test Note When using the operator terminal for the first time remember to reset the real time clock RTC Human Machi...

Страница 16: ...on Link The operator terminal is connected Confg Sets up the internal time clock and communication parameters in the operator terminal All the settings has to be made for the operator terminal to work properly Use and to move to desired field and to set the value of the field Copy Copies application data to another CP415 Set Calibrates the touch panel and adjusts LCD contrast See also section 6 5 ...

Страница 17: ... Parameters There are two ways to configure working parameters to set parameters in the operator terminal or in CP400Soft To set parameters in the operator terminal select Confg in the system menu To set parameters in CP400Soft select Application Workstation Setup Select the Connection tab to set communication parameters Note The bench test will clear the application data of the operator terminal ...

Страница 18: ...command Set is used Then per form the following steps 1 Touch the upper left and lower right corners of the screen 2 Follow the route on the screen 3 Touch the square on the center of the screen to complete the task See also section 6 2 System Menu Note When using the Set command all RAM data will be cleared ...

Страница 19: ...le the file before downloading it The file has to be compiled every time a change has been made in the file before downloading it Then select Application Download Firmware Application in CP400Soft if it is a first time to download the application to the operator terminal otherwise se lect Application Download Application The following appears on the screen while the operator terminal is downloadin...

Страница 20: ...will prompt for a password enter the password set in CP400Soft from Application Workstation Setup Once the correct password is entered the operator terminal starts to upload the application to the PC For information about setting a password please see section 6 9 Passwords While the operator terminal is uploading the following is displayed After uploading select File Reconstruct Source in CP400Sof...

Страница 21: ...enu from the operator terminal with the application to be copied The operator terminal will prompt for a password enter the pass word set in CP400Soft from Application Workstation Setup Once the correct password is entered the CP415 starts to copy the application to the other CP415 For information about setting a password please see section 6 9 Passwords The following appears on the screens during...

Страница 22: ... to access the table Touch the password to highlight an area for entering a value How to configure an Action Button is described in the CP400Soft User s Manual After registering passwords and user levels set the dip switch SW6 ON i e password required Restart the operator terminal and after the self test the user will be prompted to enter a password in order to run the operator terminal The operat...

Страница 23: ...n button can be designed with a high level of security which means that a password with a high level of privilege is required in order to open the other screen As the button is selected and the current user has a low er privilege than has been set for the button the operator terminal will prompt the user for a password The user will need a password with at least the level of privilege that has bee...

Страница 24: ...re 69685 Chassieu France Tel 33 0 4 72 22 17 22 Fax 33 0 4 72 22 17 00 ABB STOTZ KONTAKT GmbH Po Box 10 16 80 69006 Heidelberg Germany Tel 49 0 6221 701 1190 Fax 49 0 6221 701 1333 www abb fr www abb de stotz kontakt Cover_MAEN958 fm Page 2 Friday August 29 2008 1 10 PM ...

Отзывы: