Operating Instructions
Busch-Wächter
®
Installation and electrical
connection
Operating Instructions | 1473-1-8136
— 9 —
Pos: 34 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 2222222222222222333333333 @ 1
6.2 Mounting
Pos: 35 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ 22222222222233222333333333 @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 36 /#Neustruktur#/Online-Dokumentation (+KNX)/Montage/Waechter/Montage - 6747 @ 28\mod_1347265188412_15.docx @ 232508 @ 22222222222233333223333 @ 1
Caution
Risk of damaging the device!
The lens of the device is sensitive and
can easily sustain damage.
-
Do not press on the lens when
opening or closing the device.
6.2.1 Installation
sites
Fig. 3: Installation sites
•
Ceiling mounting in narrow rooms is not recommended.
•
The mounting height of the device should be between 1.7 m and 2.5. m.
•
The distance between light and movement detector should be at least 1.5 m.
•
For optimum detection of persons the approach into the detection range should always be offset and never
frontal.
>1,
7
m