![ABB AquaMaster4 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/abb/aquamaster4/aquamaster4_operating-instruction_3334002009.webp)
AQUA M A STE R4
| EL EC T R O M AG N E T I C FLO W M E T ER T R A N SM I T T ER | O I/FE T4 0 0 - EN R E V. D
9
3 Product identification labels
Nameplate – FET41X/43X
Integral transmitter
0122
EU-TEC No. T11851
Assembled YYYY/MM
SW:
3KXF208402U0113
Supply:
Battery:3.6Vdc (2xD Cell)
Logger:
ABB
Enclosure:
IP68 (NEMA 6P)
Size:
DN40 Temp. Class: T50
Accuracy:
Class 2 MAP: 16 bar
Q3:
40mˆ3/hr Q3/Q1: R250
Env. Class:
O, E2 Temp. Amb.: -25°C to +55°C
U5/D5
Δ
p
40
XXXXXXXXXXXXXXXXXXXXX
.XXX.XXX.XXX
Replace original batteries by YYYY/MM
FLOW
FLOW
FLOW
AquaMaster4
FIRE MAIN REGULAR
METER EX26564
Installation
DOC.:SS/FET400-EN
A
Model type/number
B
Transmitter-specific tag
C
ABB-defined product serial number
D
Min./Max. voltage rating
E
Logger (shown if available)
F
Enclosure ingress protection rating
G
Transmitter disposal categories
H
Applicable certification
I
OIML R49 class
J
Sensor size
K
Temperature class
L
Maximum admissable pressure
M
Highest flow rate within rated operating conditions
N
Ambient temperature
O
Environmental and electromagnetic class
P
Software number
Q
Installation sensitivity class
R
Pressure loss class
Figure 3 Name plate – integral transmitter (example)
Remote-mount transmitter
0122
EU-TEC No. T11851
Assembled YYYY/MM
SW:
3KXF208402U0113
Supply:
~95-240Vac, 50/60Hz, 3VA + Backup
Logger:
ABB
Enclosure:
IP68 (NEMA 6P)
Env. Class:
O, E2 Temp. Amb.:-25°C to +55°C
XXXXXXXXXXXXXXXXXXXXX
.XXX.XXX.XXX
FLOW
FLOW
FLOW
AquaMaster4
FIRE MAIN REGULAR
METER EX26564
Installation
DOC.:SS/FET400-EN
A
Model type/number
B
Transmitter-specific tag
C
ABB-defined product serial number
D
Min./Max. voltage rating
E
Logger (shown if available)
F
Enclosure ingress protection rating
G
Transmitter disposal categories
H
Applicable certification
I
Ambient temperature
J
Environmental and electromagnetic class
K
Software number
Figure 4 Name plate – remote-mount transmitter (example)
0122
EU-TEC No. T11851
Assembled YYYY/MM
SW:
3KXF208402U0113
Supply:
Battery:3.6Vdc (2xD Cell)
Logger:
ABB
Enclosure:
IP68 (NEMA 6P)
Size:
DN40 Temp. Class: T50
Accuracy:
Class 2 MAP: 16 bar
Q3:
40mˆ3/hr Q3/Q1: R250
Env. Class:
O, E2 Temp. Amb.: -25°C to +55°C
U5/D5
Δ
p
40
XXXXXXXXXXXXXXXXXXXXX
.XXX.XXX.XXX
Replace original batteries by YYYY/MM
FLOW
FLOW
FLOW
AquaMaster4
FIRE MAIN REGULAR
METER EX26564
Installation
DOC.:SS/FET400-EN
I
J
K
L
M
P
Q
R
N
O
0122
EU-TEC No. T11851
Assembled YYYY/MM
SW:
3KXF208402U0113
Supply:
~95-240Vac, 50/60Hz, 3VA + Backup
Logger:
ABB
Enclosure:
IP68 (NEMA 6P)
Env. Class:
O, E2 Temp. Amb.:-25°C to +55°C
XXXXXXXXXXXXXXXXXXXXX
.XXX.XXX.XXX
FLOW
FLOW
FLOW
AquaMaster4
FIRE MAIN REGULAR
METER EX26564
Installation
DOC.:SS/FET400-EN
K
I
J
Note
: For some configurations of the product, only some of the items listed will be printed on the labels.