Parameters and firmware blocks
166
(1)
Absolute
Speed error window control active. The boundaries defined by
parameters
are absolute.
(2)
Relative
Speed error window control active. The boundaries defined by
parameters
are relative to speed reference.
26.11
SPEED WIN HI
(see above)
Defines the upper boundary of the speed error window. Depending on the setting of parameter
, this is either an absolute value or relative to speed reference.
0…3000 rpm
Upper boundary of speed error window.
26.12
SPEED WIN LO
(see above)
Defines the lower boundary of the speed error window. Depending on the setting of parameter
, this is either an absolute value or relative to speed reference.
0…3000 rpm
Lower boundary of speed error window.