Parameters and firmware blocks
87
13.03
AI1 MIN
(see above)
Defines the minimum value for analogue input AI1. The type is selected with jumper J1 on the JCU
Control Unit.
-11…11 V / -22…22 mA
Minimum AI1 input value.
13.04
AI1 MAX SCALE
(see above)
Defines the real value that corresponds to the maximum analogue input value defined by parameter
-32768…32768
Real value corresponding to value of parameter
13.05
AI1 MIN SCALE
(see above)
Defines the real value that corresponds to the minimum analogue input value defined by parameter
. See parameter
.
-32768…32768
Real value corresponding to value of parameter
Firmware block:
AI2
(13)
Filters and scales the analogue input
AI2 signal and selects the AI2
supervision. Also shows the value of
the input.
Block outputs located in other
parameter groups
(page
)
(page
)
13.06
AI2 FILT TIME
(see above)
Defines the filter time constant for analogue input AI2. See parameter
0…30 s
Filter time constant for AI2.
13.07
AI2 MAX
(see above)
Defines the maximum value for analogue input AI2. The type is selected with jumper J2 on the JCU
Control Unit.
AI
(mA / V)
AI
(real)
AI2
24
TLF7 2 msec
(7)
13.06 AI2 FILT TIME
[ 0.000 s ]
13.07 AI2 MAX
[ 10.000 mA ]
13.08 AI2 MIN
[ -10.000 mA ]
13.09 AI2 MAX SCALE
[ 100.000 ]
13.10 AI2 MIN SCALE
[ -100.000 ]
2.06 AI2
2.07 AI2 SCALED
Содержание ACSM1 Series
Страница 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Страница 2: ......
Страница 4: ......
Страница 12: ...Table of contents 12...
Страница 49: ...Drive control and features 49...
Страница 282: ...Standard function blocks 282...
Страница 306: ...Application program template 306...
Страница 312: ...Control chain block diagrams 312...
Страница 331: ...331...
Страница 332: ...332...
Страница 333: ......