Parameters 355
Refresh
Refreshing.
1
Displays the parameter table revision of the fieldbus adapter
module mapping file (stored in the memory of the drive).
In format axyz, where ax = major table revision number; yz =
minor table revision number.
This parameter is read-only.
-
Parameter table revision of adapter module.
-
Displays the drive type code in the fieldbus adapter module
mapping file (stored in the memory of the drive).
This parameter is read-only.
-
0…65535
Drive type code stored in the mapping file.
1 = 1
Displays the fieldbus adapter module mapping file revision
stored in the memory of the drive in decimal format.
This parameter is read-only.
-
0…65535
Mapping file revision.
1 = 1
Displays the status of the fieldbus adapter module
communication.
-
Not configured
Adapter is not configured.
0
Initializing
Adapter is initializing.
1
Time out
A timeout has occurred in the communication between the
adapter and the drive.
2
Configuration error
Adapter configuration error: mapping file not found in the file
system of the drive, or mapping file upload has failed more
than three times.
3
Off-line
Fieldbus communication is off-line.
4
On-line
Fieldbus communication is on-line, or fieldbus adapter has
been configured not to detect a communication break. For
more information, see the documentation of the fieldbus
adapter.
5
Reset
Adapter is performing a hardware reset.
6
Displays the patch and build versions of the adapter module
firmware in format xxyy, where xx = patch version number, yy
= build version number.
Example: C802 = 200.02 (patch version 200, build version 2).
Patch and build versions of adapter module firmware.
-
Displays the major and minor versions of the adapter module
firmware in format xyy, where x = major revision number, yy =
minor revision number.
Example: 300 = 3.00 (major version 3, minor version 00).
Major and minor versions of adapter module firmware.
-
55
Selection of data to be transferred from drive to fieldbus
controller through fieldbus adapter B.
Parameters
select data to be transferred from
the drive to the fieldbus controller through fieldbus adapter B.
None
None.
0
CW 16bit
Control Word (16 bits)
1
Ref1 16bit
Reference REF1 (16 bits)
2
Ref2 16bit
Reference REF2 (16 bits)
3
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...