126 Parameters
ACS800-compatible warning (alarm) word 1.
The bit assignments of this word correspond to ALARM
WORD 1 in the ACS800. Parameter
determines whether the assignments are
according to the ACS800 Standard or ACS800 System control
program.
Each may indicate several ACS880 warnings as listed below.
This parameter is read-only.
-
0000h…FFFFh
ACS800-compatible warning (alarm) word 1.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
ACS800 alarm name
ACS880 events indicated by this bit
(see
, page
=
)
)
0
START INHIBIT
START INHIBI
1
Reserved
EM STOP
2
THERMISTOR
MOTOR TEMP M
3
MOTOR TEMP
MOTOR TEMP
4
ACS800 TEMP
ACS800 TEMP
5
ENCODER ERR
ENCODER ERR
6
T MEAS ALM
T MEAS CIRC
7
Reserved
DIGITAL IO
-
8
Reserved
ANALOG IO
-
9
Reserved
EXT DIGITAL IO
-
10
Reserved
EXT ANALOG IO
11
Reserved
CH2 COMM LOSS
12
COMM MODULE
MPROT SWITCH
13
Reserved
EM STOP DEC
-
14
EARTH FAULT
EARTH FAULT
15
Reserved
SAFETY SWITC