Parameters 125
ACS800-compatible fault word 2.
The bit assignments of this word correspond to FAULT WORD
2 in the ACS800. Parameter
determines whether the bit assignments are
according to the ACS800 Standard or ACS800 System control
program.
Each bit can indicate several ACS880 events as listed below.
This parameter is read-only.
-
0000h…FFFFh
ACS800-compatible fault word 2.
1 = 1
(Only visible with a BCU control unit)
Indicates which parallel-connected modules have faulted.
The bits of this word are cleared when all faults have been
reset.
This parameter is read-only.
-
0000h…FFFFh
Faulted modules indication.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
ACS800 fault name
ACS880 events indicated by this bit
(see
, page
)
(
=
)
0
SUPPLY PHASE
SUPPLY PHASE
1
NO MOT DATA
NO MOTOR DATA -
2
DC UNDERVOLT
DC UNDERVOLT
3
Reserved
CABLE TEMP
4
RUN ENABLE
RUN DISABLE
5
ENCODER ERR
ENCODER ERR
6
I/O COMM
IO COMM ERR
7
CTRL B TEMP
CTRL B TEMP
-
8
EXTERNAL FLT
SELECTABLE
9
OVER SWFREQ
OVER SWFREQ
-
10
AI < MIN FUNC
AI<MIN FUNC
11
PPCC LINK
PPCC LINK
,
12
COMM MODULE
COMM MODULE
13
PANEL LOSS
PANEL LOSS
14
MOTOR STALL
MOTOR STALL
15
MOTOR PHASE
MOTOR PHASE
Bit
Name
Description
0
Module 1
1 = Module 1 faulted
1
Module 2
1 = Module 2 faulted
…
…
…
11
Module 12
1 = Module 12 faulted
12…15 Reserved
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...