Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
DI5 / uint32
When bit 0 of parameter
is 0 (Separate), selects a source that activates constant
speed 1.
When bit 0 of parameter
is 1 (Packed), this parameter and parameters
and
select three sources whose states activate constant
speeds as follows:
Constant
speed active
Source
defined by
par.
Source
defined by
par.
Source
defined by
par.
None
0
0
0
Constant
speed 1
0
0
1
Constant
speed 2
0
1
0
Constant
speed 3
0
1
1
Constant
speed 4
1
0
0
Constant
speed 5
1
0
1
Constant
speed 6
1
1
0
Constant
speed 7
1
1
1
Constant speed sel1
22.22
0
0
Not selected
1
1
Selected
2
Digital input DI1 (
, bit 0).
DI1
3
Digital input DI2 (
, bit 1).
DI2
4
Digital input DI3 (
, bit 2).
DI3
5
Digital input DI4 (
, bit 3).
DI4
6
Digital input DI5 (
, bit 4).
DI5
7
Digital input DI6 (
, bit 5).
DI6
10
Digital input/output DIO1 (
, bit
0).
DIO1
11
Digital input/output DIO2 (
, bit
1).
DIO2
See
Terms and abbreviations (page 130)
Other [bit]
266 Parameters
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...