Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0
Stop by switching off the output semiconductors of
the drive.
The motor coasts to a stop.
WARNING!
If a mechanical brake is used, ensure it is safe
to stop the drive by coasting.
Coast
1
Stop along the active deceleration ramp. See parameter
group
23 Speed reference ramp (page 270)
Ramp
2
Stop according to torque limits (parameters
and
).
Torque limit
DIIL (95.20 b10);
Selected (95.20 b5);
DI5 (95.20 b9) /
uint32
Selects the source of the external run enable signal. If
the run enable signal is switched off, the drive will not
start. If already running, the drive will stop according
to the setting of parameter
.
1 = Run enable signal on.
Note: The warning that indicates a missing signal can
be suppressed using parameter
See also parameter
Run enable 1 source
20.12
0
0
Not selected
1
1
Selected
2
Digital input DI1 (
, bit 0).
DI1
3
Digital input DI2 (
, bit 1).
DI2
4
Digital input DI3 (
, bit 2).
DI3
5
Digital input DI4 (
, bit 3).
DI4
6
Digital input DI5 (
, bit 4).
DI5
7
Digital input DI6 (
, bit 5).
DI6
10
Digital input/output DIO1 (
, bit
0).
DIO1
11
Digital input/output DIO2 (
, bit
1).
DIO2
30
Control word bit 3 received through fieldbus interface
A.
FBA A MCW bit 3
32
Control word bit 3 received through the embedded
fieldbus interface.
EFB MCW bit 3
33
DIIL input (
, bit 15).
DIIL
Parameters 247
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...