Parameters 297
Selects the transfer rate of the fieldbus link.
Changes to this parameter take effect after the control unit
is rebooted or the new settings validated by parameter
9.6 kbps
9.6 kbit/s.
2
19.2 kbps
19.2 kbit/s.
3
38.4 kbps
38.4 kbit/s.
4
57.6 kbps
57.6 kbit/s.
5
76.8 kbps
76.8 kbit/s.
6
115.2 kbps
115.2 kbit/s.
7
Selects the type of parity bit and the number of stop bits.
Changes to this parameter take effect after the control unit
is rebooted or the new settings validated by parameter
8 NONE 1
Eight data bits, no parity bit, one stop bit.
0
8 NONE 2
Eight data bits, no parity bit, two stop bits.
1
8 EVEN 1
Eight data bits, even parity bit, one stop bit.
2
8 ODD 1
Eight data bits, odd parity bit, one stop bit.
3
Validates any changes in the EFB settings, or activates
silent mode.
Enabled
Normal operation.
0
Refresh settings
Validates any changed EFB configuration settings. Reverts
automatically to
.
1
Silent mode
Activates silent mode (no messages are transmitted).
Silent mode can be terminated by activating the
selection of this parameter.
2
No.
Name/Value
Description
Def/
FbEq16
Содержание ACS880 ESP
Страница 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Страница 4: ......
Страница 28: ...28 PCP ESP control start up ...
Страница 30: ...30 Using the control panel ...
Страница 94: ...94 Standard programposi features ...
Страница 100: ...100 Default control connections ...
Страница 360: ...360 Parameters ...
Страница 362: ...362 Additional parameter data Fieldbus addresses Refer to the User s Manual of the fieldbus adapter ...
Страница 436: ...436 Fault tracing ...
Страница 486: ...486 Control chain diagrams ...
Страница 492: ...492 Appendix ESP with step up transformer and sine filter ...
Страница 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...