General notes
■
Static electricity
WARNING!
Use a grounding wrist band when you handle printed circuit boards. Do not touch
the boards unnecessarily. The boards contain components sensitive to electrostatic
discharge.
■
Optical components
WARNING!
Obey these instructions. If you ignore them, damage to the equipment can occur.
•
Handle the fiber optic cables with care.
•
When you unplug the fiber optic cables, always hold the connector, not the cable itself.
•
Do not touch the ends of the fibers with bare hands as the ends are extremely sensitive
to dirt.
•
Do not bend the fiber optic cables too tightly. The minimum allowed bend radius is
35 mm (1.4”).
Measuring the insulation of brake resistor and resistor
cable
WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death, or
damage to the equipment can occur.
If you are not a qualified electrical professional, do not do installation or
maintenance work.
1.
Stop the drive and do the steps in section
Electrical safety precautions (page 50)
before
you start the work.
2.
Make sure that the resistor cable is connected to the resistor and disconnected from
the drive output terminals.
3.
At the drive end, connect the R+ and R- conductors of the resistor cable together.
Measure the insulation resistance between the conductors and the PE conductor with
a measuring voltage of 1000 V DC. The insulation resistance must be higher than
1 Mohm.
R-
R+
ohm
PE
1 kV DC,
> 1 Mohm
Electrical installation 51
11
Содержание ACS880-604
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 604 3 phase brake units as modules Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 10: ...10 ...
Страница 34: ...Overview of kits 34 Cabinet construction ...
Страница 35: ...Stage 1 Installation of common parts Cabinet construction 35 10 ...
Страница 36: ...Stage 2A Installation of DC busbars 1 without DC switch or charging 36 Cabinet construction ...
Страница 37: ...Stage 2B Installation of DC busbars 1 with DC switch and charging Cabinet construction 37 10 ...
Страница 38: ...Stage 3 Installation of quick connector and outgoing resistor busbars cable connection 38 Cabinet construction ...
Страница 39: ...Stage 4 Installation of incoming resistor busbars cable connection Cabinet construction 39 10 ...
Страница 40: ...Stage 5 Installation of mounting plates and cable entries 40 Cabinet construction ...
Страница 41: ...Stage 6 Installation of support plate Cabinet construction 41 10 ...
Страница 42: ...Stage 7 Installation of shrouding 42 Cabinet construction ...
Страница 43: ...Stage 8 Installation of brake chopper module Cabinet construction 43 10 ...
Страница 44: ...44 ...
Страница 48: ...48 ...
Страница 56: ...56 ...
Страница 74: ...74 ...
Страница 76: ...76 ...
Страница 112: ...Frame R8i 112 Dimension drawings ...
Страница 113: ...Dimension drawings 113 ...
Страница 114: ...Control electronics BCU control unit 114 Dimension drawings ...
Страница 123: ...Miscellaneous components Quick connector for frame R8i Dimension drawings 123 ...
Страница 124: ...124 Dimension drawings ...
Страница 125: ... Insertion extraction ramp for frame R8i modules Dimension drawings 125 ...
Страница 126: ...126 Dimension drawings ...
Страница 127: ... CRBB 4 400 188 cooling fan 218 Dimension drawings 127 ...
Страница 128: ...128 Dimension drawings ...