Cabinet
■
Cleaning the interior of the cabinet
WARNING!
Obey the safety instructions given in
ACS880 multidrive cabinets and
modules safety instructions
(3AUA0000102301 [English]). If you ignore
the safety instructions, injury or death, or damage to the equipment can
occur.
If you are not a qualified electrical professional, do not do installation or
maintenance work.
WARNING!
Use a vacuum cleaner with antistatic hose and nozzle, and wear a grounding
wristband. Using a normal vacuum cleaner creates static discharges which can
damage circuit boards.
1.
Stop the drive and do the steps in section
Electrical safety precautions (page 57)
before
you start the work.
2.
Open the cabinet door.
3.
Clean the interior of the cabinet. Use a vacuum cleaner and a soft brush.
4.
Clean the air inlets of the fans and air outlets of the modules (top).
5.
Clean the air inlet gratings (if any) on the door.
6.
Close the door.
■
Cleaning the door air inlets (IP22 and IP42)
Check the dustiness of the air inlet meshes. If the dust cannot be removed by vacuum
cleaning from outside through the grating holes with a small nozzle, proceed as follows:
1.
Stop the drive and do the steps in section
Electrical safety precautions (page 57)
before
you start the work.
2.
Remove the fasteners at the top of the grating.
3.
Lift the grating and pull it away from the door.
4.
Vacuum clean or wash the grating on both sides.
5.
Reinstall the grating in reverse order.
Maintenance 99
Содержание ACS880-107
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 107 inverter units Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 10: ...10 ...
Страница 64: ...2 4 5 6 7 8 11 10 3 a b a b b 1 5 a 64 Electrical installation ...
Страница 69: ...Electrical installation 109 5 6 4 3 Electrical installation 69 11 ...
Страница 70: ...7 a b d c 110 Electrical installation 7 8 8 8 9 9 70 Electrical installation ...
Страница 75: ...2 11 b PE 10 7 5 6 8 a 360 grounding detail Electrical installation 75 11 ...
Страница 89: ...With FDPI 02 modules OPEN TERMIN ATED 1 1 2 2 OPEN TERMINATED 3 Electrical installation 89 11 ...
Страница 90: ...90 ...
Страница 96: ...96 ...
Страница 110: ...4 5 6 7 8 6 10 10 110 Maintenance ...
Страница 118: ...2 3 7 9 a a c c c 6 8 b b d d 11 e e 118 Maintenance ...
Страница 121: ...7 a b d c 110 Electrical installation 7 8 8 8 9 9 Maintenance 121 ...
Страница 130: ...130 ...
Страница 154: ...154 ...
Страница 155: ...Circuit diagrams Refer to the circuit diagrams delivered with the unit 9 Circuit diagrams 155 ...
Страница 156: ...156 ...
Страница 159: ... Dimension drawing 400 mm wide cubicle R1i R4i 400 mm R6i R7i Dimensions and weights 159 ...
Страница 161: ... Dimension drawing R8i without C128 or H353 bottom cable exit Dimensions and weights 161 ...
Страница 162: ... Dimension drawing R8i without C128 or H353 top cable exit 162 Dimensions and weights ...
Страница 163: ... Dimension drawing 2 R8i without C128 or H353 bottom cable exit Dimensions and weights 163 ...
Страница 164: ... Dimension drawing 2 R8i without C128 or H353 top cable exit 164 Dimensions and weights ...
Страница 165: ... Dimension drawing 3 R8i without C128 or H353 bottom cable exit Dimensions and weights 165 ...
Страница 166: ... Dimension drawing 3 R8i without C128 or H353 top cable exit 166 Dimensions and weights ...
Страница 167: ... Dimension drawing drive control unit DCU 300 mm Dimensions and weights 167 ...
Страница 169: ...Inverter module cubicle with one R8i module top cable exit Dimensions and weights 169 ...
Страница 177: ...Cubicle width 300 mm top cable exit 246 Dimensions Cubicle width 300 mm top cable exit Dimensions and weights 177 ...
Страница 179: ...Cubicle width 400 mm top cable exit Cubicle width 400 mm top cable exit Dimensions and weights 179 ...
Страница 181: ...Cubicle width 600 mm top cable exit Cubicle width 600 mm top cable exit Dimensions and weights 181 ...
Страница 182: ...182 ...
Страница 200: ...200 ...