I/O Settings

In the I/O Settings mode, you can:

• check the parameter settings related to any I/O terminal

• edit the parameter setting 

• start, stop, change the direction and switch between local and remote control.

How to edit and change parameter settings related to I/O terminals

Step

Action

Display

1.

Go to the Main menu by pressing 

 if you are in the Output mode, otherwise 

by pressing 

 repeatedly until you get to the Main menu.

2.

Go the I/O Settings mode by selecting I/O SETTINGS on the menu with keys 

 and 

, and pressing 

.

Select the I/O group, e.g. Digital inputs, with keys 

 and 

.

3.

Press 

. After a brief pause, the display shows the current settings for the 

selection.

You can scroll digital inputs and parameters with keys 

 and 

.

4.

Press 

. The panel shows information related to I/O selected (in this case, 

DI1).

You can scroll information with keys 

 and 

.

Press 

 to return to the digital inputs.

5.

Select the setting (line with a parameter number) with keys 

 and 

You can edit the parameter (INFO selection turns into EDIT selection).

6.

Press . 

MENU

EXIT

                     

PARAMETERS 

ASSISTANTS

CHANGED PAR

EXIT

ENTER

00:00

MAIN MENU

1

LOC

ENTER

                     

Analog outputs

Analog inputs

Digital I/Os

Digital inputs

Relay outputs

EXIT

SEL

00:00

I/O SETTINGS

1

LOC

                     

Analog outputs

Analog inputs

Digital I/Os

Digital inputs

Relay outputs

EXIT

SEL

00:00

I/O SETTINGS

4

LOC

SEL

                     

DI1

1002 Ext1 start in1

DI2

DI3

1010 Fault reset sel

I/O SETTINGS

1

LOC

EXIT

INFO

00:00

INFO

EXIT

LOC

EXIT

00:00

                     

NUM OF I/O ITEMS

0

SLOT NUMBER

0

NODE NUMBER 

I/O INFO

                     

DI1

1002 Ext1 start in1

DI2

DI3

1010 Fault reset sel

I/O SETTINGS

1

LOC

EXIT

EDIT

00:00

EDIT

                     

                     

1002 Ext1 start in1

                     

                     

                     

PAR EDIT

DI1

CANCEL

SEL

00:00

[P.02.01.00]

LOC

Содержание ACS850 series

Страница 1: ...ACS850 User s Guide ACS850 Control Panel...

Страница 2: ......

Страница 3: ...ACS850 Control Panel User s Guide 3AUA0000050277 Rev A EN EFFECTIVE 02 01 2009 2009 ABB Oy All Rights Reserved...

Страница 4: ......

Страница 5: ...What this chapter contains 13 Connecting the panel to the drive 13 Mounting the control panel on the cabinet door 14 The cable 14 Operation What this chapter contains 15 Basics of operation 15 List o...

Страница 6: ...w and edit changed parameters 29 Fault Logger 30 How to view faults 30 How to reset faults 31 Time Date 32 How to show or hide the clock change display formats set the date and time and enable or disa...

Страница 7: ...ging the default settings of the function For warnings and notes see appropriate Firmware Manual Intended audience This manual is intended for persons who install and use the panel Product and service...

Страница 8: ...About the manual 8...

Страница 9: ...using the panel in control monitoring and changing the settings About control panels Use a control panel to control the ACS850 read status data and adjust parameters Compatibility The manual is compa...

Страница 10: ...e context The text in the lower left corner of the LCD display indicates the function 4 Soft key 2 Function depends on the context The text in the lower right corner of the LCD display indicates the f...

Страница 11: ...arrow Drive is running at setpoint Dotted rotating arrow Drive is running but not at setpoint Stationary arrow Drive is stopped Dotted stationary arrow Start command is present but the motor is not r...

Страница 12: ...Hardware description 12...

Страница 13: ...ins The chapter describes connecting and mounting of the control panel Connecting the panel to the drive The control panel connection to ACS850 drive is shown in the figure below See also hardware man...

Страница 14: ...e ACS CP U Control Panel IP54 Mounting Platform Kit Installation Guide 3AUA0000049072 English The cable CAT5 straight through network cable max 3 m can be used The cable is available from ABB but othe...

Страница 15: ...the relevant soft key With the right soft key you usually enter a mode accept an option or save the changes The left soft key is used to cancel the made changes and return to the previous operation l...

Страница 16: ...parameter to point to the value of a bit in another signal Parameters PARAMETERS 24 How to change the value of bit pointer parameter to fixed 0 FALSE or 1 TRUE Parameters PARAMETERS 26 How to select t...

Страница 17: ...r the drive 2 Keep key pressed down while you switch on the power and read the information The display shows the following panel information Panel SW panel firmware version ROM CRC panel ROM check sum...

Страница 18: ...To switch to local control LOC and control the drive using the control panel press The result depends on how long you press the key If you release the key immediately the display flashes Switching to...

Страница 19: ...7 for instructions on selecting and modifying the monitored signals How to change the direction of the motor rotation Step Action Display 1 If you are not in the Output mode press repeatedly until you...

Страница 20: ...nce value shown in the top right corner of the display press The value changes immediately It is stored in the permanent memory of the drive and restored automatically after power switch off To decrea...

Страница 21: ...ess 5 Specify a new value for the parameter with keys and Pressing the key once increments or decrements the value Holding the key down changes the value faster Pressing the keys simultaneously replac...

Страница 22: ...e the new value press To cancel the new value and keep the original press Step Action Display SAVE CANCEL 9906 Mot nom current 3 5 A 9907 Mot nom voltage 9908 Mot nom freq 9909 Mot nom speed PARAMETER...

Страница 23: ...of each parameter is shown below it 5 Press Current value of the value pointer parameter is shown as well as the parameter it points to 6 Specify a new value with keys and The parameter the value poin...

Страница 24: ...u are in the Output mode otherwise by pressing repeatedly until you get to the Main menu 2 Go to the Parameters option by selecting PARAMETERS on the menu with keys and and pressing 3 Select the appro...

Страница 25: ...r the bit pointer parameter press To cancel the new value and keep the original press The new value is shown in the parameters list Step Action Display 1002 Ext1 start in1 DI6 PAR EDIT CANCEL SEL 00 0...

Страница 26: ...lect the appropriate parameter group Select the appropriate parameter with keys and Current value of each parameter is shown below its name 4 Press Select CONST with keys and 5 Press 6 Specify a new c...

Страница 27: ...ructions on changing parameter values Note If you set one of the parameters 56 01 56 03 to zero in the output mode you can see names for two remaining signals The names are also shown if you set one o...

Страница 28: ...to the Main menu 2 Go to the Assistants mode by selecting ASSISTANTS on the menu with keys and and pressing 3 Motor Set up assistant under Firmware assistants is used as an example Select Firmware as...

Страница 29: ...parameter is shown below it 3 Press to modify the value 4 Specify a new value for the parameter with keys and Pressing the key once increments or decrements the value Holding the key down changes the...

Страница 30: ...rrective actions are listed in appropriate firmware manual 3 To see the details of a fault select it with keys and and press Scroll the text with keys and To return to the previous display press 4 If...

Страница 31: ...to reset faults Step Action Display 1 When a fault occurs text identifying the fault is shown To reset the fault press To return to the previous display press RESET EXIT FAULT 36 LOCAL CTRL LOSS FAUL...

Страница 32: ...ISIBILITY on the menu press select Show clock Hide clock with keys and and press or if you want to return to the previous display without making changes press To specify the time format select TIME FO...

Страница 33: ...saving time is used in each country or area whose daylight saving changes you can select to be followed Scroll the text with keys and To return to the previous display press To disable automatic clock...

Страница 34: ...kup stored in the control panel with SHOW BACKUP INFO This includes e g version information etc of the current backup file in the panel It is useful to check this information when you are going to res...

Страница 35: ...the Par Backup with keys and Press Restoring starts Backup interface version is checked Scroll the text with keys and If you want to continue press Press if you want to stop the operation If the down...

Страница 36: ...by pressing 3 The panel shows details about the version check For details of the information fields shown on the control panel see section How to view information about the backup on page 41 You can...

Страница 37: ...ows a message about it Downloading continues drive is being restarted The display shows the transfer status as a percentage of completion Downloading continues Downloading finishes Initializing param...

Страница 38: ...me Press when you have edited parameters Step Action Display 1 Restore operation starts normally 2 Version check is also OK You can see on the panel that the firmware versions are not the same You can...

Страница 39: ...is being restarted 8 Downloading finishes 9 Panel shows a text identifying the alarm and returns to the Par Backup Step Action Display Initializing param restore operation PAR BACKUP LOC 00 00 Restar...

Страница 40: ...he parameter group 16 Select parameter 16 09 USER SET SEL with keys and Current value of each parameter is shown below its name 3 Press Select the user set you want to load with keys and Press 4 Panel...

Страница 41: ...rmware version e g 1 330 0 Firmware patch version PRODUCT VARIANT 1 ACSM1 Speed 2 ACSM1 Motion 3 ACS850 Standard Control Program 4 ACS850 FA Variant for factory applications You can scroll the informa...

Страница 42: ...nd 4 Press The panel shows information related to I O selected in this case DI1 You can scroll information with keys and Press to return to the digital inputs 5 Select the setting line with a paramete...

Страница 43: ...faster Pressing the keys simultaneously replaces the displayed value with the default value 8 To save the new value press To cancel the new value and keep the original press Step Action Display 1002...

Страница 44: ...he Output mode otherwise by pressing repeatedly until you get to the Main menu 3 Go to the Reference Edit option by selecting REF EDIT on the menu with keys and and pressing 4 Select the correct sign...

Страница 45: ...mmissioning and maintenance tool DRIVE TYPE e g ACS850 DRIVE MODEL Type code of the drive FW VERSION See page 41 SOLUTION PROGRAM Version information of the active solution program BASE SOLUTION PROGR...

Страница 46: ...parameter has been changed twice it is shown as one change in the list The current value of the parameter and the parameter change date and time are also shown below the selected parameter You can scr...

Страница 47: ......

Страница 48: ...3AUA0000050277 Rev A EN EFFECTIVE 02 01 2009 ABB Oy AC Drives P O Box 184 FI 00381 HELSINKI FINLAND Telephone 358 10 22 11 Fax 358 10 22 22681 Internet www abb com...

Отзывы: