Hardware description 11
Example: upright position, frames R4 to R9
Degree of protection
This table shows the degree of protection of the flange-mounted drive. In frames R1,
R2, R4 and R5 to R9 the degree of protection of IP55 (UL Type 12) for the front is not
possible because the cover cannot be installed.
Frame size
Plus code
Degree of
protection
Degree of protection with flange
Front
Back
R1
-
IP21 (UL Type 1)
IP20 (UL Open Type)
IP55 (UL Type 12)
R1
B056
IP55 (UL Type 12)
IP20 (UL Open Type)
IP55 (UL Type 12)
R2
-
IP21 (UL Type 1)
IP20 (UL Open Type)
IP55 (UL Type 12)
R2
B056
IP55 (UL Type 12)
IP20 (UL Open Type)
IP55 (UL Type 12)
R3
-
IP21 (UL Type 1)
IP20 (UL Open Type)
IP55 (UL Type 12)
R3
B056
IP55 (UL Type 12)
IP55 (UL Type 12)
IP55 (UL Type 12)
R4
-
IP21 (UL Type 1)
IP20 (UL Open Type)
IP55 (UL Type 12)
R4
B056
IP55 (UL Type 12)
IP20 (UL Open Type)
IP55 (UL Type 12)
R5
-
IP21 (UL Type 1)
IP20 (UL Open Type)
IP55 (UL Type 12)
R6
-
IP21 (UL Type 1)
IP20 (UL Open Type)
IP55 (UL Type 12)
R7
-
IP21 (UL Type 1)
IP20 (UL Open Type)
IP55 (UL Type 12)
1
Hood (in the cooling air
channel; required for UL
Type 12)
2
Top flange bracket
3
Mounting plate
4
Lifting hole
5
Drive heat sink in the cooling
air channel
6
Side flange bracket
7
Drive front side
8
Bottom flange bracket
1
4
7
5
2
3
6
4
8
4
4
Содержание ACS580-01 Series
Страница 1: ... ABB DRIVES ACS580 01 ACH580 01 and ACQ580 01 C135 drives with flange mounting kit Supplement ...
Страница 2: ... ...
Страница 4: ......
Страница 16: ...16 Mechanical installation General ...
Страница 46: ...46 Mechanical installation Frames R4 and R5 ...
Страница 56: ...56 Dimension drawings Frame R1 3AXD50000131310 ...
Страница 57: ...Dimension drawings 57 3AXD50000131242 Hood is needed for UL Type 12 installation only ...
Страница 58: ...58 Dimension drawings Attaching points and hole dimensions 3AXD50000035517 ...
Страница 59: ...Dimension drawings 59 Frame R2 3AXD50000131327 ...
Страница 60: ...60 Dimension drawings 3AXD50000131242 Hood is needed for UL Type 12 installation only ...
Страница 61: ...Dimension drawings 61 Attaching points and hole dimensions 3AXD50000035597 ...
Страница 62: ...62 Dimension drawings Frame R3 3AXD50000131143 ...
Страница 63: ...Dimension drawings 63 3AXD50000130870 Hood is needed for UL Type 12 installation only ...
Страница 64: ...64 Dimension drawings Attaching points and hole dimensions 3AXD50000036519 ...
Страница 65: ...Dimension drawings 65 Frame R4 3AXD50000038122 ...
Страница 66: ...66 Dimension drawings 3AXD50000038179 Hood is needed for UL Type 12 installation only ...
Страница 67: ...Dimension drawings 67 Attaching points and hole dimensions 3AXD50000036765 ...
Страница 68: ...68 Dimension drawings Frame R5 3AXD50000038123 ...
Страница 69: ...Dimension drawings 69 3AXD50000038180 Hood is needed for UL Type 12 installation only ...
Страница 70: ...70 Dimension drawings Attaching points and hole dimensions 3AXD50000430598 ...
Страница 71: ...Dimension drawings 71 Frame R6 3AXD50000021919 ...
Страница 72: ...72 Dimension drawings Hood is needed for UL Type 12 installation only 3AXD50000021919 ...
Страница 73: ...Dimension drawings 73 Attaching points and hole dimensions 3AXD50000019323 ...
Страница 74: ...74 Dimension drawings Frame R7 3AXD50000021920 ...
Страница 75: ...Dimension drawings 75 Hood is needed for UL Type 12 installation only 3AXD50000021920 ...
Страница 76: ...76 Dimension drawings Attaching points and hole dimensions 3AXD50000019324 ...
Страница 77: ...Dimension drawings 77 Frame R8 3AXD50000021921 ...
Страница 78: ...78 Dimension drawings Hood is needed for UL Type 12 installation only 3AXD50000021921 ...
Страница 79: ...Dimension drawings 79 Attaching points and hole dimensions 3AXD50000019325 ...
Страница 80: ...80 Dimension drawings Frame R9 3AXD50000021922 ...
Страница 81: ...Dimension drawings 81 3AXD50000021922 Hood is needed for UL Type 12 installation only ...
Страница 82: ...82 Dimension drawings Attaching points and hole dimensions 3AXD50000019326 ...