ABB ACS550-U2 Скачать руководство пользователя страница 3

Installation Supplement for ACS550-U2 Drives

3

Safety

Safety

General

In this manual, ACS550 refers, unless otherwise stated, to type ACS550-U2.

Warning! The ACS550 adjustable speed AC drive should ONLY be installed by 
a qualified electrician.

Warning! Even when the motor is stopped, dangerous voltage is present at the 
Power Circuit terminals U1, V1, W1 and U2, V2, W2 and UDC+, UDC-.

Warning! Even when power is removed from the input terminals of the 
ACS550, there may be dangerous voltage (from external sources) on the 
terminals of the relay outputs RO1…RO3 or on option modules.

Warning! Dangerous voltage is present when input power is connected. After 
disconnecting the supply, wait at least 5 minutes (to let the intermediate circuit 
capacitors discharge) before removing any covers. 

Warning! The ACS550-U2 is field repairable by qualified personnel only. To 
service or repair a malfunctioning unit, contact your local Authorized Service 
Center.

Warning! The ACS550 will start up automatically after an input voltage 
interruption if the external run command is on.

Warning! When the control terminals of two or more drive units are connected 
in parallel, the auxiliary voltage for these control connections must be taken 
form a single source, which can either be one or the units, or an external 
supply.

Warning! The heat sink may reach a high temperature. See Technical Data 
chapter in User’s Manual.

Use of Warnings and Notes

There are two types of safety instructions throughout this manual:

Notes draw attention to a particular condition or fact, or give information on a 
subject. 

Warnings caution you about conditions which can result in serious injury or death 
and/or damage to the equipment. They also tell you how to avoid the danger. The 
warning symbols are used as follows:

Dangerous voltage warning warns of high voltage which can cause physical injury 
and/or damage to the equipment. 

General warning warns about conditions, other than those caused by electricity, 
which can result in physical injury and/or damage to the equipment.

Содержание ACS550-U2

Страница 1: ...DriveIT Low Voltage AC Drives Installation Supplement ACS550 U2 Drives 150 550 HP ...

Страница 2: ...ical product description including Dimensional drawings Cabinet mounting information including power losses Software and control including complete parameter descriptions User interfaces and control connections Complete options descriptions Spare parts Etc Practical Engineering Guides PID PFC engineering guides Dimensioning and sizing guidelines Diagnostics and Maintenance information Etc OPTION M...

Страница 3: ...thorized Service Center Warning The ACS550 will start up automatically after an input voltage interruption if the external run command is on Warning When the control terminals of two or more drive units are connected in parallel the auxiliary voltage for these control connections must be taken form a single source which can either be one or the units or an external supply Warning The heat sink may...

Страница 4: ...tents Safety General 3 Use of Warnings and Notes 3 Table of Contents Installation Introduction 5 Planning 5 Moving the Unit 5 Mounting 6 Connecting Power and Control Cables 6 Maintenance Safety 9 Separating the Drive and Extension Modules 9 Technical Data Dimensional Drawings 11 ...

Страница 5: ...nsion module This supplement requires and routinely refers to the document ACS550 02 U2 User s Manual WARNING Only qualified electricians are allowed to carry out the work described in this chapter Follow requirements in Safety on the first pages of this manual Ignoring the safety instructions can cause injury or death Planning When planning for cable conduit routing refer to the ACS550 02 U2 User...

Страница 6: ...the drive module Connecting Power and Control Cables Additional considerations that apply with the enclosure extension The power cable connection diagram that applies for the ACS550 U2 is Temporarily remove the upper high voltage shield clear plastic to gain access to the power connections in the extension module To avoid metal shavings inside the cabinet temporarily remove the gland conduit plate...

Страница 7: ...e The following diagram shows the power and control connection points in the enclosure module supplied with the R7 drive module PDM 146378 8 Switch Fuse Input U1 V1 W1 Output U2 V2 W2 PE Connection Gland Conduit Plate OMIO Board Control Wiring Terminals and Option Module Mounts R7 Frame Size Cable fittings shown are typical examples ...

Страница 8: ...age shield Warning Always replace all high voltage shields before applying power See the ACS550 02 U2 User s Manual for detailed instructions on control connections installation check list and drive start up process Switch Fuse Input U1 V1 W1 Output U2 V2 W2 PE Connection OMIO Board Control Wiring Terminals and Option Module Mounts R8 Frame Size Gland Conduit Plate Cable fittings shown are typical...

Страница 9: ... that the drive module and trolley can roll forward for service access 1 Disconnect all power sources from the drive extension modules and wait at least 5 minutes for internal capacitors to fully discharge 2 Remove all front covers from the drive module 3 Disconnect the control panel cable 4 Remove the upper side plate from the drive module if convenient 5 Remove screws if any that fasten the driv...

Страница 10: ...l not get damaged or caught in the trolley when the drive module is wheeled out 10 Remove screws fastening the drive module trolley to the pedestal Warning These screws are an important step during re assembly the screws are required for grounding the drive 11 R8 The front of the trolley includes support braces that fold out Lift each brace slightly and fold it out 12 Remove screws that fasten the...

Страница 11: ...or ACS550 U2 Drives 11 Technical Data Technical Data Dimensional Drawings See the ACS550 02 U2 User s Manual for drive module dimensions Extension Module R7 3AFE 64626264 30 04 02 Dimensions are listed in millimeters and inches ...

Страница 12: ...12 Installation Supplement for ACS550 U2 Drives Technical Data Detail Dimensions are listed in millimeters and inches ...

Страница 13: ...Installation Supplement for ACS550 U2 Drives 13 Technical Data Extension Module R8 3AFE 64626388 30 04 02 US gland conduit Dimensions are listed in millimeters and inches ...

Страница 14: ...14 Installation Supplement for ACS550 U2 Drives Technical Data Detail Dimensions are listed in millimeters and inches ...

Страница 15: ...Installation Supplement for ACS550 U2 Drives 15 Technical Data ...

Страница 16: ... 22 11 Telefax 358 10 22 22681 Internet http www abb com ABB Inc Automation Technologies Drives Machines 16250 West Glendale Drive New Berlin WI 53151 USA Telephone 262 785 3200 800 HELP 365 Telefax 262 780 5135 3AUA0000004067 REV A EN EFFECTIVE Oct 22 2003 SUPERSEDES None ...

Отзывы: