168 Actual signals and parameters
Group 12: Constant speeds
This group defines a set of constant speeds. In general:
• You can program up to 7 constant speeds, ranging from 0 … 500 Hz.
• Values must be positive (No negative speed values for constant speeds).
• Constant speed selections are ignored if:
- the torque control is active, or
- the process PID reference is followed, or
- the drive is in local control mode, or
- PFA (Pump and fan alternation) is active
Note:
acts also as a so-called fault speed which
may be activated if the control signal is lost. For example, see parameters
and
.
1107
REF2 MIN
0.0 … 100.0%
(torque: 0 … 600%)
0.1%
0.0%
Sets the minimum for external reference 2.
• The minimum analog input signal (in volts or amps) corresponds to REF2 MIN in %.
• Parameter
sets the minimum analog
input signal.
• This parameter sets the minimum frequency reference.
• The value is a percentage of the:
• maximum frequency or speed
• maximum process reference
• nominal torque.
1108
REF2 MAX
0.0 … 100.0%
(torque: 0 … 600%)
0.1%
100.0%
Sets the maximum for external reference 2.
• The maximum analog input signal (in volts or amps) corresponds to REF2 MAX in
%.
• Parameter
sets the maximum analog
input signal.
• This parameter sets the maximum frequency reference.
• The value is a percentage of the:
• maximum frequency or speed
• maximum process reference
• nominal torque
Group 11: Reference select
Code
Description
Range
Resolution
Default
S
Содержание ACS320 series
Страница 1: ...ABB drives User s manual ACS320 drives 0 5 to 30 hp ...
Страница 4: ......
Страница 18: ...18 Safety ...
Страница 28: ...28 Operation principle and hardware description ...
Страница 56: ...56 Electrical installation ...
Страница 142: ...142 Program features Connection diagram example ACS320 xx xxxx x ...
Страница 282: ...282 Actual signals and parameters ...
Страница 358: ...358 Fieldbus control ...
Страница 376: ...376 Fault tracing ...
Страница 382: ...382 Maintenance and hardware diagnostics ...
Страница 407: ...Dimension drawings 407 Frame size R2 NEMA 1 Frame size R2 IP20 NEMA 1 3AUA0000051097 A ...
Страница 409: ...Dimension drawings 409 Frame size R3 NEMA 1 Frame size R3 IP20 NEMA 1 3AUA0000051118 A ...
Страница 411: ...Dimension drawings 411 Frame size R4 NEMA 1 Frame size R4 IP20 NEMA 1 3AUA0000051133 A ...
Страница 412: ...412 Dimension drawings ...
Страница 413: ...Index Numerics A B C D E F G H I K L M N O P R S T ...
Страница 442: ...www abb com drives www abb com drivespartners 3AUA0000062599 Rev E EN EFFECTIVE 2016 07 05 Contact us 3AUA0000062599E ...