204 Actual signals and parameters
DI1
Digital input DI1.
1 = Motor heating is On.
0 = Motor heating is Off.
1
DI2
See selection
.
2
DI3
See selection
.
3
DI4
See selection
.
4
DI5
See selection
.
5
COMM
Serial communication as the control for motor heating.
7
ON
Motor heating active (during stop)
8
DI1(INV)
Inverted digital input DI. 0 = Motor heating On 1 = Motor
heating Off.
-1
DI2(INV)
See selection
-2
DI3(INV)
See selection
-3
DI4(INV)
See selection
-4
DI5(INV)
See selection
-5
22 ACCEL/DECEL
Acceleration and deceleration times
2201 ACC/DEC 1/2
SEL
Defines the source from which the drive reads the signal
that selects between the two ramp pairs,
acceleration/deceleration pair 1 and 2.
Ramp pair 1 is defined by parameters
Ramp pair 2 is defined by parameters
NOT SEL
Ramp pair 1 is used.
0
DI1
Digital input DI1. 1 = ramp pair 2, 0 = ramp pair 1.
1
DI2
See selection
.
2
DI3
See selection
.
3
DI4
See selection
.
4
DI5
See selection
.
5
COMM
Fieldbus interface as the source for ramp pair 1/2 selection,
bit 10. The Control
word is sent by the fieldbus controller through the
embedded fieldbus (Modbus) to the drive. For the Control
word bits, see section
on page
Note:
This setting applies only for the DCU profile.
7
DI1(INV)
Inverted digital input DI1. 0 = ramp pair 2, 1 = ramp pair 1.
-1
DI2(INV)
See selection
-2
DI3(INV)
See selection
-3
DI4(INV)
See selection
-4
DI5(INV)
See selection
-5
All parameters
No.
Name/Value
Description
Def/FbEq