Fault tracing 347
Other
-
Contact your local ABB representative,
quoting the auxiliary code.
73B0
Emergency ramp
failed
Emergency stop did not
finish within expected time.
Check the settings of parameters
Check the predefined ramp times
(
…
for mode Off1,
for
mode Off3).
8001
ULC underload fault
User load curve: Signal has
been too long under the
underload curve.
See parameter
8002
ULC overload fault
User load curve: Signal has
been too long over the
overload curve.
See parameter
80A0 AI supervision
Programmable fault:
An analog signal is outside
the limits specified for the
analog input.
Check signal level at the analog input.
Check the wiring connected to the
input.
Check the minimum and maximum
limits of the input in parameter group
80B0 Signal supervision
(Editable message
text)
Programmable fault:
Fault generated by the signal
supervision 1 function.
Check the source of the fault
80B1
Signal supervision
(Editable message
text)
Programmable fault:
Fault generated by the signal
supervision 2 function.
Check the source of the fault
).
80B2 Signal supervision
(Editable message
text)
Programmable fault:
Fault generated by the signal
supervision 3 function.
Check the source of the fault
).
80B3 Signal supervision
(Editable message
text)
Programmable fault:
Fault generated by the signal
supervision 4 function.
Check the source of the fault
).
80B4 Signal supervision
(Editable message
text)
Programmable fault:
Fault generated by the signal
supervision 5 function.
Check the source of the fault
).
Code
(hex) Fault / Aux. code
Cause
What to do
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...