150 Parameters
Min (ref1, ref2)
The smaller of the reference sources is used as speed
reference 1.
4
Max (ref1, ref2)
The greater of the reference sources is used as speed
reference 1.
5
Determines how constant speeds are selected, and
whether the rotation direction signal is considered or
not when applying a constant speed.
0b0001
0b0000...ob1111
Constant speed configuration word.
1 = 1
When bit 0 of parameter
is 0 (Separate), selects a source that
activates constant speed 1.
Always off
0 (always off).
0
Always on
1 (always on).
1
DI1
Digital input DI1 (
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
Supervision 1
.
24
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Information
0
Constant
speed mode
1 = Packed: 7 constant speeds are selectable using the three
,
.
0 = Separate: Constant speeds 1, 2 and 3 are separately activated by
the sources defined by parameters
and
respectively. In case of conflict, the constant speed with the smaller
number takes priority.
1
Direction
enable
1 = Start dir: To determine running direction for a constant speed,
the sign of the constant speed setting (parameters
multiplied by the direction signal (forward: +1, reverse: -1). This
effectively allows the drive to have 14 (7 forward, 7 reverse)
constant speeds if all values in
are positive.
WARNING!
If the direction signal is reverse and the active
constant speed is negative, the drive will run in the forward
direction.
0 = According to Par: The running direction for the constant
frequency is determined by the sign of the constant speed setting
).
Source defined
Source defined
Source defined
Constant speed active
0
0
0
None
0
0
0
Constant speed 1
0
0
0
Constant speed 2
1
1
0
Constant speed 3
0
0
1
Constant speed 4
1
0
1
Constant speed 5
0
1
1
Constant speed 6
1
1
1
Constant speed 7
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...