Fieldbus control
231
Setting up communication through a fieldbus adapter module
Fieldbus adapters for several communication protocols are available (for example,
PROFIBUS and Modbus). Rxxx type fieldbus adapter modules are mounted in
expansion slot 1 of the drive. Nxxx type fieldbus adapter modules are connected to
channel CH0 of the RDCO module.
Note:
For instructions on setting up an RMBA-01 module, see section
communication through the Standard Modbus Link
Before configuring the drive for fieldbus control, the adapter module must be
mechanically and electrically installed according to the instructions given in the
hardware manual of the drive, and the module manual.
The following table lists the parameters which need to be defined when setting up
communication through a fieldbus adapter.
Parameter
Alternative
settings
Setting for
fieldbus control
Function/Information
COMMUNICATION INITIALISATION
NO
FIELDBUS
ADVANT
STD MODBUS
CUSTOMISED
FIELDBUS
Initialises communication between drive and
fieldbus adapter module. Activates module set-up
parameters (Group 51).
ABB DRIVES
GENERIC
CSA 2.8/3.0
ABB DRIVES
GENERIC or
CSA 2.8/3.0
Selects the communication profile used by the
drive. See section
on page
ADAPTER MODULE CONFIGURATION
51.01 MODULE
TYPE
–
–
Displays the type of the fieldbus adapter module.
51.02 (FIELDBUS
PARAMETER 2)
These parameters are adapter-module-specific. For more information, see the module manual.
Note that not all of these parameters are necessarily visible.
• • •
51.26 (FIELDBUS
PARAMETER 26)
51.27 FBA PAR
REFRESH*
(0)
DONE
(1)
REFRESH
–
Validates any changed adapter module
configuration parameter settings. After refreshing,
the value reverts automatically to DONE.
51.28 FILE CPI
FW REV*
xyz (binary coded
decimal
–
Displays the required CPI firmware revision of the
fieldbus adapter as defined in the configuration file
stored in the memory of the drive. The CPI firmware
version of the fieldbus adapter (refer to Par. 51.32)
must contain the same or a later CPI version to be
compatible.
x
= major revision number;
y
= minor
revision number;
z
= correction number.
Example
:
107
= revision 1.07.
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...