Fieldbus control
233
Setting up communication through the Standard Modbus Link
An RMBA-01 Modbus Adapter installed in slot 1 or 2 of the drive forms an interface
called the Standard Modbus Link. The Standard Modbus Link can be used for
external control of the drive by a Modbus controller (RTU protocol only).
Before configuring the drive for Modbus control, the adapter module must be
mechanically and electrically installed according to the instructions given in the
hardware manual of the drive, and the module manual.
The following table lists the parameters, which need to be defined when setting up
communication through the standard Modbus link.
After the communication parameters in group 52 STANDARD MODBUS have been
set, the drive control parameters (section
on page
)
must be checked and adjusted where necessary.
Parameter
Alternative settings
Setting for control
through Standard
Modbus Link
Function/Information
COMMUNICATION INITIALISATION
NO
FIELDBUS
ADVANT
STD MODBUS
CUSTOMISED
STD MODBUS
Initialises communication between drive
(Standard Modbus Link) and Modbus-protocol
controller. Activates communication parameters
in group 52.
ABB DRIVES
GENERIC
CSA 2.8/3.0
ABB DRIVES
Selects the communication profile used by the
drive. See section
page
.
COMMUNICATION PARAMETERS
1 to 247
–
Specifies the station number of the drive on the
Standard Modbus Link.
600
1200
2400
4800
9600
19200
–
Defines the communication speed for the
Standard Modbus Link.
ODD
EVEN
NONE1STOPBIT
NONE2STOPBIT
–
Selects the parity setting for the Standard
Modbus Link.
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...