ACS 600 MultiDrive
B-1
Marine Applications – Technical Data
Ratings
The supply, braking and drive section tables in
apply to marine applications with the following notes.
Note Concerning Height:
The height in the tables does not include vibration dampers
(18 mm at bottom and 72 mm on top of the cabinet). The additional height due to the
dampers is 90 mm.
Note Concerning Depth:
The basic depth of the cabinet without door devices is
600 mm. Additional 50 mm is required at the back and in front of the cabinet for the
vibration dampers. Maximum depth (including flash barriers and hand grips on the
door) is 758 mm.
Note:
not all types are available for marine applications
Cabinet
The cabinet, degrees of protection and free space requirements for
marine applications are listed below.
1)
R = air outlet duct
2)
200 between rear plates of the cabinets when installed back to back
Ambient Conditions
The ambient conditions given in
ACS 600 MultiDrive – Technical Data
apply to marine applications with the following exception:
ACx 600 Type
Enclosure
Degree of
Protection
Space
above
mm
Space
below
mm
Space on
left/right
mm
Space in
front/back
mm
ACS 600 MarineDrive
Cabinet
IP 22, IP 42,
IP 54 R
1)
500
0
0
200/100
2)
Condition
Operation
installed for stationary use
Storage
in the protective package
Transportation
in the protective package
Vibration
(IEC 68-2-6)
Amplitude ± 1,0 mm
(5 to 13,2 Hz)
Acceleration 7m/s
2
(13,2 to 100 Hz)
Amplitude ± 1,0 mm
(5 to 13,2 Hz)
Acceleration 7m/s
2
(13,2 to 100 Hz)
Amplitude ± 1,0 mm
(5 to 13,2 Hz)
Acceleration 7m/s
2
(13,2 to 100 Hz)