du/dt Filters Installation Guide
7
•
NOCH0xxx-6x
filters are designed to cool by natural convection, thus the
following free space requirements apply:
Wall-mounted filter units:
300 mm on each free side.
Exception:
500 mm above the filter if installed below
the drive.
Floor-mounted filter units:
300 mm on each free side.
Exception:
50 mm between single-phase filters on
the same transmission line.
Exception:
500 mm above the filter if installed
below the drive.
Technical data
Nominal voltage:
380 … 690 V ± 10%.
Rated short-time withstand current:
50 kA 1 s.
Applicable standards and markings:
EN 60204-1, EN 60529, EN 61800-3,
EN 50178, CE marking, UL approval.
Ambient conditions, operation
Ambient operating conditions refer to the conditions du/dt filters are subjected to
when installed for stationary use.
Air temperature:
-15 to +50
°
C. At temperatures from +40
°
C to +50
°
C, the rated
output current is decreased by 1% for every additional 1
°
C. The output current is
calculated by multiplying the current given in the rating table by the derating factor.
Relative humidity:
5% to 95%, no condensation allowed. Maximum allowed relative
humidity is 60% in the presence of corrosive gases.
Installation site altitude:
0 to 4000 m. At altitudes from 1000 to 4000 m above the
sea level, the rated output current is decreased by 1% for every 100 m.
Vibration:
AOCH0xxx-70: Max 1 mm (5 to 13.2 Hz), max 7 m/s
2
(13.2 to 100 Hz) sinusoidal
(IEC 60068-2)
NOCH0xxx-6x: Max 0.3 mm (2 to 9 Hz), max 1 m/s
2
(9 to 200 Hz) sinusoidal
(IEC60068-2)
Shock:
Max 70 m/s
2
, 22 ms (IEC 60068-2-27)
Содержание ACS 600 MultiDrive
Страница 2: ...3AFE 58933368 REV D EN EFFECTIVE 20 10 2003 2003 ABB Oy All Rights Reserved...
Страница 4: ...Table of contents 4...
Страница 10: ...du dt Filters Installation Guide 10 Power connections NOCH0260 60 NOCH0400 60 NOCH0760 60 NOCH0400 60...
Страница 12: ...du dt Filters Installation Guide 12 NOCH0760 60...
Страница 13: ...du dt Filters Installation Guide 13 NOCH0400 60...
Страница 14: ...du dt Filters Installation Guide 14 NOCH0400 60...
Страница 15: ...du dt Filters Installation Guide 15 AOCH0400 70 AOCH0260 70...
Страница 23: ...du dt Filters Installation Guide 23...
Страница 24: ...du dt Filters Installation Guide 24 NOCH0760 60 Weight 43 kg 95 lbs 1 1 2 1 1 2 2 2...
Страница 25: ...du dt Filters Installation Guide 25...
Страница 26: ...du dt Filters Installation Guide 26 64787845 A NOCH0120 62 NOCH0120 65 Weight 45 kg 99 lbs...
Страница 27: ......