Additional parameter data 191
40.62 PID internal setpoint actual
-200000.00...200000.00
PID
customer
units
100 = 1 PID
customer unit
40.79 Set 1 units
0...31
Depends
on
selection
-
40.89 Set 1 setpoint multiplier
-200000.00...200000.00
-
-
40.90 Set 1 feedback multiplier
-200000.00...200000.00
-
100 = 1
40.91 Feedback data storage
-327.68…327.67
-
100 = 1
40.92 Setpoint data storage
-327.68…327.67
-
100 = 1
40.96 Process PID output%
-100.00...100.00
%
-
40.97 Process PID feedback%
-100.00...100.00
%
-
40.98 Process PID setpoint%
-100.00...100.00
%
-
40.99 Process PID deviation%
-100.00...100.00
%
-
46 Monitoring/scaling settings
46.01 Speed scaling
0.00…30000.00
rpm
100 = 1 rpm
46.02 Frequency scaling
0.10…1000.00
Hz
100 = 1 Hz
46.03 Torque scaling
0.1…1000.0
%
10 = 1%
46.04 Power scaling
0.10…30000.00 kW or
0.10…40200.00 hp
kW or hp
10 = 1 unit
46.05 Current scaling
0…30000
A
1 = 1 A
46.06 Speed ref zero scaling
0.00 … 30000.00
rpm
100 = 1 rpm
46.07 Frequency ref zero scaling
0.00 … 1000.00
Hz
100 = 1 Hz
46.11 Filter time motor speed
2…20000
ms
1 = 1 ms
46.12 Filter time output frequency
2…20000
ms
1 = 1 ms
46.13 Filter time motor torque
2…20000
ms
1 = 1 ms
46.14 Filter time power
2…20000
ms
1 = 1 ms
46.21 At speed hysteresis
0.00…30000.00
rpm
100 = 1 rpm
46.22 At frequency hysteresis
0.00…1000.00
Hz
100 = 1 Hz
46.31 Above speed limit
0.00…30000.00
rpm
100 = 1 rpm
46.32 Above frequency limit
0.00…1000.00
Hz
100 = 1 Hz
46.41 kWh pulse scaling
0.001…1000.000
kWh
1000 = 1 kWh
46.43 Power decimals
0...3
-
1 = 1
46.44 Current decimals
0...3
-
1 = 1
49 Panel port communication
49.01 Node ID number
1…32
-
1 = 1
49.03 Baud rate
1…5
-
1 = 1
49.04 Communication loss time
0.3…3000.0
s
10 = 1 s
49.05 Communication loss action
0…3
-
1 = 1
49.06 Refresh settings
0…1
-
1 = 1
50 Fieldbus adapter (FBA)
50.01 FBA A enable
0…1
-
1 = 1
50.02 FBA A comm loss func
0…5
-
1 = 1
50.03 FBA A comm loss t out
0.3…6553.5
s
10 = 1 s
50.04 FBA A ref1 type
0...2, 4, 5
-
1 = 1
50.05 FBA A ref2 type
Not applicable
50.06 FBA A SW sel
0…1
-
1 = 1
50.07 FBA A actual 1 type
-
-
1 = 1
50.08 FBA A actual 2 type
Not applicable
50.09 FBA A SW transparent source
-
-
1 = 1
50.10 FBA A act1 transparent source
-
-
1 = 1
50.11 FBA A act2 transparent source
Not applicable
50.12 FBA A debug mode
0…1
-
1 = 1
50.13 FBA A control word
0.0.0.0.0...FF.FF.FF.FF
-
1 = 1
50.14 FBA A reference 1
-2147483648…
2147483647
-
1 = 1
No.
Name
Type
Range
Unit
FbEq32
ACQ80 FW.book Page 191 Thursday, February 14, 2019 11:33 AM
Содержание ACQ80-04 Series
Страница 4: ...4 ACQ80 FW book Page 4 Thursday February 14 2019 11 33 AM ...
Страница 10: ...10 Table of contents ACQ80 FW book Page 10 Thursday February 14 2019 11 33 AM ...
Страница 16: ...16 Introduction to the manual ACQ80 FW book Page 16 Thursday February 14 2019 11 33 AM ...
Страница 26: ...26 Start up control with I O and ID run ACQ80 FW book Page 26 Thursday February 14 2019 11 33 AM ...
Страница 28: ...28 Using the control panel ACQ80 FW book Page 28 Thursday February 14 2019 11 33 AM ...
Страница 54: ...54 Program features ACQ80 FW book Page 54 Thursday February 14 2019 11 33 AM ...
Страница 196: ...196 Additional parameter data ACQ80 FW book Page 196 Thursday February 14 2019 11 33 AM ...
Страница 220: ...220 Fault tracing ACQ80 FW book Page 220 Thursday February 14 2019 11 33 AM ...
Страница 260: ...260 Fieldbus control through a fieldbus adapter ACQ80 FW book Page 260 Thursday February 14 2019 11 33 AM ...
Страница 264: ...264 Parameterization with drive composer ACQ80 FW book Page 264 Thursday February 14 2019 11 33 AM ...
Страница 268: ...268 Parameterization with automation builder drive manager ACQ80 FW book Page 268 Thursday February 14 2019 11 33 AM ...