Operation Manual / A200-L
9 Disassembly and assembly / 9.16 Fitting the nozzle ring (A280-L)
© Copyright 2021 ABB. All rights reserved.
HZTL4036_EN
Rev.T
December 2021
Fig. 55: Attaching the nozzle ring (A280-L)
Part number
A280-L
56014
M12
65 Nm
Table 36: Tightening torque (56014)
1. Fit the nozzle ring holder (90477) on the flange of the gas inlet casing (51001) with
screws (B
1
).
2. Remove screws (B
2
).
3. Align the notch (A
1
) on the cam of the nozzle ring (56001) with the flange connection (A
2
)
and slide the nozzle ring into the gas inlet casing.
4. Coat screws (56014) with high-temperature grease and fit with washers (56011).
5. Remove screws (B
1
) along with the nozzle ring holder (90477).
Page
97
/
145