Operation Manual / A200-L
7 Periodic maintenance / 7.3 Changing the filter strip on the filter silen-
cer casing
© Copyright 2021 ABB. All rights reserved.
HZTL4036_EN
Rev.T
December 2021
Fig. 19: Attaching new filter ring
u
Attach the new filter ring (81265) on the filter ring to be replaced so they overlap.
Fig. 20: Fitting new filter ring
u
Pull on the old filter ring until the new filter ring is completely wrapped around the filter
silencer.
u
Undo the connection between the new and the old filter ring.
u
Fasten the newly installed filter ring (81265), then fit circumferential part (9).