ABB Welcome
®
— 5 —
4.2
Operating modes
4.2.1
Mode=1, works as an independent outdoor station
Fig. 2: Mode=1, works as an independent outdoor station
Rotary
Value
Note
Mode
1
Camera interface works as an independent camera interface.
Addr
null
——
ID
2
ID starts from 1 to 9 sequentially, and should not be the same address
as the camera interface or any other camera interface.
Dip Switch 1-4
Turn to ON when a camera is connected.
Capacity
Each camera interface supports four analog cameras.
A total of nine camera interfaces (mode=1) may be supported in one system.
Operation
Press
to view the cameras individually during surveillance.