ABB 4234 600 Скачать руководство пользователя страница 11

PRODUCTS & CUSTOMER SUPPORT

Products

Automation Systems

for the following industries:

– Chemical & Pharmaceutical
– Food & Beverage
– Manufacturing
– Metals and Minerals
– Oil, Gas & Petrochemical
– Pulp and Paper

Drives and Motors

AC and DC Drives, AC and DC Machines, AC motors to 1kV

Drive systems

Force Measurement

Servo Drives

Controllers & Recorders

Single  and Multi-loop Controllers

Circular Chart , Strip Chart and Paperless Recorders

Paperless Recorders

Process Indicators

Flexible Automation

Industrial Robots and Robot Systems

Flow Measurement

Electromagnetic Magnetic Flowmeters

Mass Flow Meters

Turbine Flowmeters

Wedge Flow Elements

Marine Systems & Turbochargers

Electrical Systems

Marine Equipment

Offshore Retrofit and Referbishment

Process Analytics

Process Gas Analysis

Systems Integration

Transmitters

Pressure

Temperature

Level

Interface Modules

Valves, Actuators and Positioners

Control Valves

Actuators

Positioners

Water, Gas & Industrial Analytics Instrumentation

pH, conductivity, and dissolved oxygen transmitters and
sensors

ammonia, nitrate, phosphate, silica, sodium, chloride,
fluoride, dissolved oxygen and hydrazine analyzers.

Zirconia oxygen analyzers, katharometers, hydrogen purity
and purge-gas monitors, thermal conductivity.

Customer Support

ABB Ltd. provides a comprehensive after sales service via a
Worldwide Service Organization. Contact one of the following
offices for details on your nearest Service and Repair Centre.

United Kingdom

ABB Ltd.
Tel: +44 (0)1453 826 661
Fax: +44 (0)1453 827 856

United States of America

ABB Inc.
Tel: +1 (0) 755 883 4366
Fax: +1 (0) 755 883 4373

Client Warranty

Prior to installation, the equipment referred to in this manual
must be stored in a clean, dry environment, in accordance with
the Company's published specification. Periodic checks must be
made on the equipment's condition.

In the event of a failure under warranty, the following
documentation must be provided as substantiation:

1. A listing evidencing process operation and alarm logs at time

of failure.

2. Copies of operating and maintenance records relating to the

alleged faulty unit.

Содержание 4234 600

Страница 1: ...4234 600 Series Power Supply Unit Instruction Manual Models 4234 600 4234 601 ...

Страница 2: ...rational conditions result in degraded process system performance leading to personal injury or death Therefore comply fully with all Warning and Caution notices Information in this manual is intended only to assist our customers in the efficient operation of our equipment Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part ...

Страница 3: ...rviceable parts Two identical fuses L N are mounted within the unit on the mains input A third fuse is connected in the d c line circuit of the transformer A fourth fuse is connected in the auxiliary 10 V d c line The L N fuses are a high breaking capacity type and must only be replaced with identical types See Section 2 for rating 1 INTRODUCTION Fig 1 1 Location of Internal Component TB1 T1 L N E...

Страница 4: ...terconnecting cable 2 Ω max Ambient Temperature Range 20 to 55 C 2 SPECIFICATION Permissible Supply Voltage Variation 15 Frequency Range 46 to 64 Hz Output Regulation Within 0 8 for a Load variation 15 b Supply variation 6 c Ambient temperature 10 C Ripple Less than 17 5 mV across 10 Ω load peak to peak Stability Within 0 7 of initial setting over a period of one month with load resistance supply ...

Страница 5: ...ore commencing installation check that the unit supplied is suitable for the supply voltage available see Section 2 and the data plate on the unit cover Fig 3 2 140 CTRS 110 CTRS 170 111 120 All holes 7 0 diameter 160 83 20 20 30 30 30 60 DIM Ensure a clearance of at least 100 mm at both ends of the unit for acces to the cable glands and to minimise cable bends Mains Cable Entry Output to Temperat...

Страница 6: ...nections for typical gas analysis systems 4 1 1 Katharometer Connections Cable connecting the constant current d c supply from the PSU to the katharometer should be selected so that the maximum cable resistance is less than 2 ohms This limits the maximum cable length between the katharometer and its associated PSU Note that the cable gland will accept a cable between 5 to 9 mm in diameter 4 1 2 Te...

Страница 7: ... assembly when supplies are connected Thus there is a risk of electrocution All normal precautions must be taken to avoid the risk of accidental electrical shock during installation and maintenance of the equipment Ensure that the supply cable is disconnected at its source before touching any electrical connections Caution Ensure that the correct version of the unit has been supplied for the suppl...

Страница 8: ...Centre or returned to the factory for repair Fig 5 1 Changing Fuses TB1 T1 L N E F2 F3 6 8 10 230 V 115 V TB2 F1 B A C X D E F4 AUX 10V Switch off and disconnect the mains supply 1 2 Remove the four screws and lift off the cover Replace fuse s 3 Note Suitable fuses may be obtained from ABB with the following part numbers F1 0231555 400 mA cartridge F2 F3 0231577 250 mA 1500 A hbc cartridge F4 0231...

Страница 9: ...7 NOTES ...

Страница 10: ...8 NOTES ...

Страница 11: ...al Analytics Instrumentation pH conductivity and dissolved oxygen transmitters and sensors ammonia nitrate phosphate silica sodium chloride fluoride dissolved oxygen and hydrazine analyzers Zirconia oxygen analyzers katharometers hydrogen purity and purge gas monitors thermal conductivity Customer Support ABB Ltd provides a comprehensive after sales service via a Worldwide Service Organization Con...

Страница 12: ...ained herein without notice Printed in UK 01 02 ABB 2002 ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel 44 0 1453 826 661 Fax 44 0 1453 827 856 ABB Inc 2175 Lockheed Way Carson City NV 89706 USA Tel 1 0 775 883 4366 Fax 1 0 775 883 4373 ABB has Sales Customer Support expertise in over 100 countries worldwide www abb com ...

Отзывы: