2  Overview 

General description 

Tina 5A is designed for bypassing of safety devices connected to the Vital or Pluto dynamic safety circuit as well as 
supervision of lamp indication. 

Bypassing of safety devices such as a light grid or an interlocked gate is in some situations only allowed if status 
information (bypassing active/inactive) is indicated. Tina 5A can therefore supervise an indication lamp (1-5 W) 
connected across L1-L2, and the bypassing signal from Tina 5A is only sent if the indication lamp is working 
properly. If no indication lamp is to be used across L1-L2 (e.g. if the status indication is performed by other means) 
an 820   / 2 W resistor must be connected across L1-L2. Whether indication is required depends on the specific 
situation and result of risk analysis.  

When the Tina 5A receives a dynamic signal to S1 and the bypass indication lamp (1-5W) is ON, a bypassing 
output signal is provided on S2 and S3. A broken indication lamp, or a short circuit within it, leads to an interruption 
of the bypass output signal on S2 and S3, therefore stopping the bypassing. 

The dynamic signal to S1 on Tina 5A must be the input signal from the first of the safety devices intended to 
bypass. The signal can be connected via output contacts from a safety relay, a safety timer or be initiated via a unit 
providing the dynamic signal as for example an Eden or a Spot. 

The dynamic output signal from S2 or S3 is to be connected to the output signal from the last safety device which is 
to be bypassed. 

Safety regulations 

 

Warning!

 

Carefully read through this entire manual before using the device. 

The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine 
directive.  

Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions, 
improper installation or handling of the device can affect the safety of people and the plant. 

For installation and prescribed use of the product, the special notes in the instructions must be carefully observed 
and the technical standards relevant to the application must be considered. 

In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the 
product, any liability is excluded. 

 

 

Содержание 2TLA020054R0400

Страница 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com lowvoltage Original instructions Tina 5A Bypassing unit ...

Страница 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attenti...

Страница 3: ...l description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 11 Installation precautions 11 Bypassing of Eden and Tina units 11 Maintenance 11 Testing of the safety functions 12 Troubleshooting 12 5 Operation 13 Information output signal attributes 13 6 Technical data 14 Dimensions 15 7 EC Declaration of conformity 16 ...

Страница 4: ... of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment...

Страница 5: ... bypass output signal on S2 and S3 therefore stopping the bypassing The dynamic signal to S1 on Tina 5A must be the input signal from the first of the safety devices intended to bypass The signal can be connected via output contacts from a safety relay a safety timer or be initiated via a unit providing the dynamic signal as for example an Eden or a Spot The dynamic output signal from S2 or S3 is ...

Страница 6: ... using an even including Tina 5A number of dynamic safety devices See connection example below drawing no HE3824D 01 an even number of dynamic safety units is to be bypassed using an odd including Tina 5A number of dynamic safety devices See connection example below drawing no HE3824E 01 8 pin connection block 2x4 terminals A1 24 VDC Y14 Information output bypass ON L1 Bypass indication lamp L2 By...

Страница 7: ...2TLC172131M0201 rev A 7 www abb com lowvoltage 2011 09 20 Connection examples Drawing number HE3824C 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 8: ...2TLC172131M0201 rev A 8 www abb com lowvoltage 2011 09 20 Drawing number HE3824F 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 9: ...2TLC172131M0201 rev A 9 www abb com lowvoltage 2011 09 20 Drawing number HE3824D 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 10: ...2TLC172131M0201 rev A 10 www abb com lowvoltage 2011 09 20 Drawing number HE3824E 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 11: ...rted with forward current out from pin 4 of the last unit in both bypassing circuits excerpt from connection example HD3801A in the Safety Handbook below Maintenance Warning The safety functions and the mechanics shall be tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 In case of breakdown or damage to the product contact the ne...

Страница 12: ...ted causes of faults Checking and measures to take Mute LED off on Tina 5A No dynamic signal to S1 Check dynamic signal input Mute resistor removed Mount a new 820 2 W resistor at terminals L1 L2 Mute LED off external Mute lamp broken Replace the mute lamp Wrong mute lamp 1 W Watt 5 W Replace the mute lamp with a suitable one No lights Loss of power supply Check 24 VDC 0 VDC power supply Weak ligh...

Страница 13: ...fety circuit is OK up until this unit No dynamic signal Dynamic signal input does not exist i e the safety circuit is interrupted before this unit 24 VDC A constant 24 VDC signal is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is al...

Страница 14: ...volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class Enclosure IP40 Connection block IP20 Ambient temperature 10 55 C Humidity range 35 to 85 with no icing or condensation Connectors Connection blocks with a total of 8 screw terminals 2 x 4 Max tightening torque 1 Nm Mounting 35 mm DIN rail Size 120 x 84 x 22 5 L x W x H Weight 135 g Colour Black and...

Страница 15: ...2TLC172131M0201 rev A 15 www abb com lowvoltage 2011 09 20 Dimensions NB All measurements in millimetres ...

Страница 16: ...d to compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including lo...

Отзывы: