background image

 

 

2TLC172131M0201, rev. A 

www.abb.com/lowvoltage 

2011-09-20  

Read and understand this document 

Please read and understand this document before using the products. Please consult your ABB/JOKAB SAFETY 
representative if you have any questions or comments. 

WARRANTY 

ABB/JOKAB SAFETY’s exclusive warranty is that the products are free from defects in materials and workmanship 
for a period of one year (or other period if specified) from date of sale by ABB/JOKAB SAFETY.  

ABB/JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, 
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF 
THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED 
USE. ABB/JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. 

LIMITATIONS OF LIABILITY 

ABB/JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL 
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, 
WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  

In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on 
which liability asserted.  

IN NO EVENT SHALL ABB/JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER 
CLAIMS REGARDING THE PRODUCTS UNLESS ABB/JOKAB SAFETY’S ANALYSIS CONFIRMS THAT THE 
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO 
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

SUITABILITY FOR USE 

ABB/JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply 
to the combination of products in the customer’s application or use of the product. At the customer’s request, 
ABB/JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of 
use that apply to the products. This information by itself is not sufficient for a complete determination of the 
suitability of the products in combination with the end product, machine, system, or other application or use.  

The following are some examples of applications for which particular attention must be given. This is not intended 
to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be 
suitable for the products:  

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not 
described in this document.  

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, 
amusement machines, vehicles, and installations subject to separate industry or government regulations.  

Systems, machines, and equipment that could present a risk to life or property.  

Please know and observe all prohibitions of use applicable to the products.  

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY 
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE ABB/JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE 
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

PERFORMANCE DATA 

While every effort has been taken to ensure the accuracy of the information contained in this manual ABB/JOKAB 
SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and 
improvements without notice. Performance data given in this document is provided as a guide for the user in 
determining suitability and does not constitute a warranty. It may represent the result of ABB/JOKAB SAFETY’S 
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to 
the ABB/JOKAB SAFETY Warranty and Limitations of Liability. 

Содержание 2TLA020054R0400

Страница 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com lowvoltage Original instructions Tina 5A Bypassing unit ...

Страница 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attenti...

Страница 3: ...l description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 11 Installation precautions 11 Bypassing of Eden and Tina units 11 Maintenance 11 Testing of the safety functions 12 Troubleshooting 12 5 Operation 13 Information output signal attributes 13 6 Technical data 14 Dimensions 15 7 EC Declaration of conformity 16 ...

Страница 4: ... of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment...

Страница 5: ... bypass output signal on S2 and S3 therefore stopping the bypassing The dynamic signal to S1 on Tina 5A must be the input signal from the first of the safety devices intended to bypass The signal can be connected via output contacts from a safety relay a safety timer or be initiated via a unit providing the dynamic signal as for example an Eden or a Spot The dynamic output signal from S2 or S3 is ...

Страница 6: ... using an even including Tina 5A number of dynamic safety devices See connection example below drawing no HE3824D 01 an even number of dynamic safety units is to be bypassed using an odd including Tina 5A number of dynamic safety devices See connection example below drawing no HE3824E 01 8 pin connection block 2x4 terminals A1 24 VDC Y14 Information output bypass ON L1 Bypass indication lamp L2 By...

Страница 7: ...2TLC172131M0201 rev A 7 www abb com lowvoltage 2011 09 20 Connection examples Drawing number HE3824C 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 8: ...2TLC172131M0201 rev A 8 www abb com lowvoltage 2011 09 20 Drawing number HE3824F 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 9: ...2TLC172131M0201 rev A 9 www abb com lowvoltage 2011 09 20 Drawing number HE3824D 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 10: ...2TLC172131M0201 rev A 10 www abb com lowvoltage 2011 09 20 Drawing number HE3824E 01 Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 11: ...rted with forward current out from pin 4 of the last unit in both bypassing circuits excerpt from connection example HD3801A in the Safety Handbook below Maintenance Warning The safety functions and the mechanics shall be tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 In case of breakdown or damage to the product contact the ne...

Страница 12: ...ted causes of faults Checking and measures to take Mute LED off on Tina 5A No dynamic signal to S1 Check dynamic signal input Mute resistor removed Mount a new 820 2 W resistor at terminals L1 L2 Mute LED off external Mute lamp broken Replace the mute lamp Wrong mute lamp 1 W Watt 5 W Replace the mute lamp with a suitable one No lights Loss of power supply Check 24 VDC 0 VDC power supply Weak ligh...

Страница 13: ...fety circuit is OK up until this unit No dynamic signal Dynamic signal input does not exist i e the safety circuit is interrupted before this unit 24 VDC A constant 24 VDC signal is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is al...

Страница 14: ...volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class Enclosure IP40 Connection block IP20 Ambient temperature 10 55 C Humidity range 35 to 85 with no icing or condensation Connectors Connection blocks with a total of 8 screw terminals 2 x 4 Max tightening torque 1 Nm Mounting 35 mm DIN rail Size 120 x 84 x 22 5 L x W x H Weight 135 g Colour Black and...

Страница 15: ...2TLC172131M0201 rev A 15 www abb com lowvoltage 2011 09 20 Dimensions NB All measurements in millimetres ...

Страница 16: ...d to compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including lo...

Отзывы: