7.2-10
Advant Controller 31 / Issued: 10.99
07 MK 92 R1161
2
Hardware
Serial interfaces COM5, COM6
Interface standard
EIA RS-232
Mode
Application mode
Electrical isolation
Both interfaces are not electrically isolated.
Connection
Connection is via removable screw-type terminal
blocks.
Serial interface COM5: Terminal assignment
Interface standard: EIA RS-232
7
9
PGND
Protective Ground (Shield)
10
TxD
Transmit Data
(Output)
11
RxD
Receive Data
(Input)
12
RTS
Request To Send (Output)
13
CTS
Clear To Send
(Input)
14
SGND
Signal Ground
(0V)
Fig. 7.2-9:
Terminal assignment of the
serial interface COM5
Serial interface COM6: Terminal assignment
Interface standard: EIA RS-232
23
PGND
Protective Ground (Shield)
24
TxD
Transmit Data
(Output)
25
RxD
Receive Data
(Input)
26
RTS
Request To Send (Output)
27
CTS
Clear To Send
(Input)
28
SGND
Signal Ground
(0V)
Fig. 7.2-10: Terminal assignment of the
serial interface COM6