background image

INSTRUCTION MANUAL

III. MAIN LIST:

2

Содержание DVL480

Страница 1: ...INES USA 14508 S Garfield Ave Paramount CA 90723 USA Tel 310 532 0366 Fax 310 532 0499 Email sales abacomachines com Website www abacomachines com ABACO MACHINES OPERATION MANUAL ABACO GLASS VACUUM LIFTER DVL480 ...

Страница 2: ...arioussizeofglass II STRUCTURE The Abaco Glass Vacuum Lifter consists of a main frame which connectedtothesuctioncupsviaajoinedbar Themainframeis attachedtothehangingbarviaswiveljoint Besides themainframeisequippedwithanelectricboxandmotor SPECIFICATION Work Load Limit Diameter of Suction Cups Number of Suction Cups Minimum Glass Dimension Power Charge 1056 lbs 480 kg 6 pc 220 V 1 phase INSTRUCTIO...

Страница 3: ...INSTRUCTION MANUAL III MAIN LIST 2 ...

Страница 4: ...480 09 Clamp 1 10 DVL480 10 Gas cylinder 1 11 DVL480 11 Cover 1 12 DVL480 12 Pad pin 1 1 13 DVL480 13 Pad pin 2 1 14 DVL480 14 Control panel 1 15 DVL480 15 Line shaft 1 1 16 DVL480 16 Conical spring 6 17 DVL480 17 Pad 1 18 DVL480 18 Solenoid box 1 19 DVL480 19 Allen cap bolt M6x10 4 20 DVL480 20 Flange 1 21 DVL480 21 Crank handle 1 22 DVL480 22 Rubber suction cup 6 23 DVL480 23 Right pad 1 POS COD...

Страница 5: ...L480 33 Allen cap screw M5x16 4 34 DVL480 34 Washer Ø20 1 35 DVL480 35 Hex bolt M20x40 1 36 DVL480 36 Allen countersunk screw M5x15 4 37 DVL480 37 Special bolt 36 38 DVL480 38 Allen cap bolt M8x20 1 39 DVL480 39 Washer Ø8 1 40 DVL480 40 Handgrip 1 41 DVL480 41 Allen cap screw M8x60 1 42 DVL480 42 Frame of change 1 43 DVL480 43 Rubber cap 40x40 2 44 DVL480 44 Rubber cap 40x60 6 45 DVL480 45 Nut M8 ...

Страница 6: ...hlywithoutanynoise 2 During Operations Caution Always pay attention to alarm signal caused by such as pressure and voltage gauges battery voltage shall be around 13VDC when fullychargedandlowersideshallbearound11VDC Stop working immediately when detected abnormal phenomena suchas noise vacuumleakage deformationofanyparts andso on Ensure maximum safety in the working area to avoid accidents whenmov...

Страница 7: ...lifter next to the glass CAUTION Adjust the suction cups to fit to the glass Refer to V 3 Adjust the suction cups position page17 Make sure the lifter is at the gravity center of the glass 4 Device Usage A UPRIGHT Glass Lifting Usage 6 ...

Страница 8: ...N MANUAL Step2 Move the lifer close to the glass surface CAUTION Make sure all of the suction cups touch the glass surface atthesametimewithevenspacing Step3 Press VACUUM green light button to suction the glass 7 ...

Страница 9: ...hows between 0 8barto 1bar Step 4 Rotate the glass During proper suctioning the glass can be rotated 90 degrees Refer toV 2 RotateSuction Cups page16 WARRNING Never press RELEASE red light button during suctioning glass Confirm the pressure gauge indicators are showing between 0 8 to 1bar If pressure indicator shows less than 0 6 bar move the system to asafepositionandfixit 8 ...

Страница 10: ...he glass handle it carefully and slowly withbestcares Do not unlock the lock lever to adjust the angle when suctioning theglass Step 6 Press RELEASE button for about 5 seconds and move thelifterawayfromtheglass Caution Make sure the two gauge indicators take back to 0 before shutthelifteroff 9 ...

Страница 11: ...ward in order to suction the glass horizontally Refer to V 1 Adjust thesuction cups fromUpright toHorizontal page15 Step1 Move the lifter near to the glass Caution Adjust the suction cups to fit to the glass Refer to V 3 Adjust the suction cups position page17 Make sure the lifter is at the gravity center of the glass 10 ...

Страница 12: ... MANUAL Step2 Move the lifter close to the glass surface Caution Make sure all of the suction cups touch the glass surfaceatthesametimewithevenspacing Step3 Press VACUUM green light button to suction the glass 11 ...

Страница 13: ...between 0 8barto 1Bar Step 4 Move the glass During proper suctioning the glass can be rotated horizontally 90 degrees RefertoV 2 RotateSuction Cups page16 WARRNING Never press RELEASE red light button during suctioning glass Confirm the pressure gauge indicator is showing between 0 8 to 1bar If pressure indicator shows less than 0 6 bar move the system to asafepositionandfixit 12 ...

Страница 14: ...MANUAL Step 5 Move the glass to the desired location CAUTION When lowering down the glass handle it carefully and slowly with bestcares Do not unlock the lock lever to adjust the angle when suctioning the glass 13 ...

Страница 15: ...INSTRUCTION MANUAL Step 6 Press RELEASE button for about 5 seconds and move thelifterawayfromtheglass Note Make sure the two gauge indicators take back to 0 before shut thelifterout 14 ...

Страница 16: ...ppendix INSTRUCTION MANUAL V 1 Adjust thesuction cups fromUpright toHorizontal Pull down the lock lever to release then carefully incline the cups tohorizontalpositionandadjusttheangleasthepicturebelow 15 ...

Страница 17: ...ip lock as shown in the picture Next rotate the glass vacuum lifter follow to your requirement Note Pin clock automatically install into hole position for angle adjustment INSTRUCTION MANUAL V 2 Rotate Suction Cups 16 ...

Страница 18: ... Loosen turn knob anticlockwise direction Move suction cup follow to requirement place tighten turn knob clockwise direction V 3 Adjusting the suction cups position INSTRUCTION MANUAL 17 ...

Страница 19: ...en damaged during shipment Any claims must be submitted within 8 days from the date of delivery We provide a one 1 year warranty on the Abaco Glass Vacuum Lifter from the date of purchase During warranty period we will provide the replacement parts at no charge shipping and handling fees may apply Warranty coverage is void if The operator failed to comply with the instructions in the manual The sp...

Страница 20: ...E18 ...

Отзывы: