Publication No. 500-657055-000 Rev. G
IPMI Firmware and OEM Extensions 53
B.1.4 Get Self-Test Results
This command returns the results of the Power-On Self Test.
Table B-4 NetFn 0x06, Cmd 0x04
Byte
Value
Data Field
Comments
Request-
data
- -
Response-
data
1
00
Completion code
2
55h
56h
57h
58h
FFh
All other
No error. All Self-Tests Passed.
Self-Test not implemented in
this controller.
Corrupted or inaccessible data
or devices.
Fatal hardware error.
Reserved.
Device-specific ‘internal’ failure.
3
XXh
If byte 2 is 55h, 56h or FFh, then
00h.
If byte 2 is 58h or All other, then
device specific.
If byte 2 is 57h, then Self-test
error bit field. 1b means ‘failed’,
0b means ‘unknown’.
[7] 1b = cannot access SEL
device
[6] 1b = cannot access SDR
repository
[5] 1b = cannot access FRU
device
[4] 1b = IPMB signal lines do not
respond
[3] 1b = SDR repository empty
[2] 1b = Internal use area of FRU
corrupted
[1] 1b = controller update ‘boot
block’ firmware corrupted
[0] 1b = controller operational
firmware corrupted