background image

SD3000 PLUS DC Drive Regulator

9

 

 

 

SD3K-CBLFWDPMxxx

SD3K-CBLCANNONxxx

SD 3K-CBLBOXA 048 (for S6)

SD3K-CBLBOXB 048 (for S6R)

(Make as short as possible.

Do not route with power leads.)

TB 

(Recommended)

SD3000 PLUS 

Retrofit of Non-Rockwell 

Power Module (S6R)

SD3K-CBLREVPMxxx

SD3K-CBLCANNONxxx

SD3K-CBLBOXB 048 (for S6R)

(Make as short as possible.

Do not route with power leads.)

TB 

(Recommended)

Mount to  608877-6A

bracket.  One bracket 
for both Motoring and 

Regenerative 

connectors.

POWER 

MODULE

FWD

REV

FWD GATES

SD3000 PLUS

REV GATES

(Drawing 97305100)

(Drawing 97305300)

(Drawing 97305401)

(Drawing 97305402)

(Drawing 97305500)

(Drawing 97305500)

6 Gate Couplers

97306101

6 Gate Couplers

97306101

Gate Coupler Assembly

SD3K-GATMDLHIGH

(9732017 * to view drawing)

SD3K-CBLFWDPMxxx

TB 

(Recommended)

SD3000 PLUS

Retrofit of Non -Rockwell 

Power Module (S6R)

SD3K-CBLCPLR072

(Make as short as possible.

Do not route with power leads.)

Gate Coupler Assembly

SD3K-GATMDLHIGH

(9732017 * to view drawing)

SD3K-CBLREVPMxxx

TB 

(Recommended)

SD3K-CBLCPLR072

(Make as short as possible.

Do not route with power leads.)

POWER 

MODULE

FWD

REV

FWD GATES

SD3000 PLUS

REV GATES

(Drawing 97329101)

(Drawing 97329101)

(Drawing 97305100)

(Drawing 97305300)

SD3000 PLUS

Retrofit of Reliance Power Module (S6R)

With “round” style gate connector and 

With O-51378-19 (or equivalent) gate couplers.

POWER 

MODULE

FWD

REV

SD3K-CBLREVPMxxx

SD3K-CBLFWDPMxxx

Reliance 

Power Module (S6R)

FWD GATES

SD3000 PLUS

REV GATES

Gate Scaling Module

(Part No. 97331001 )

SD3K-CBLGSCLIRxxx

Gate Scaling Module

(Part No. 97331001 )

SD 3K-CBLGSCLIFxxx

(Drawing 97330000 )

(Drawing 97330100 )

(Drawing 97305100 )

(Drawing 97305300 )

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание SD3000 PLUS

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ... followed DO NOT work alone on energized equipment ATTENTION The installation of the drive must be planned such that all cutting drilling tapping and welding can be accomplished with the drive removed from the enclosure The drive is of the open type construction and any metal debris must be kept from falling into the drive Metal debris or other foreign matter may become lodged in the drive circuit...

Страница 3: ... when installing testing servicing or repairing this assembly Component damage may result if ESD control procedures are not followed If you are not familiar with static control procedures reference A B publication 8000 4 5 2 Guarding Against Electrostatic Damage or any other applicable ESD protection handbook GP COM OK FDBK OK LP P M FLT RPI OK EXT FLT XMT RCV L1 L2 MCR AUX IN 1 AUX IN 2 AUX IN 3 ...

Страница 4: ...r connectors and cable bend radius in front of unit 3 25 82 55 11 63 295 40 5 25 133 35 1 03 26 162 11 09 281 686 0 31 7 874 10 06 255 524 12 01 305 054 12 98 329 692 Weight kg lbs Drive Regulator Drive Regulator Packaging 7 03 15 5 7 71 17 0 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 5: ...ire Size Range Torque Maximum Minimum Recommended Input Power Terminal Block L1 L2 Ground Input power 94809302 4 0 mm2 10 AWG 2 5 mm2 14 AWG 0 677909 N m 6 lb in Ground Stud Chassis Ground Use grounding cable kit 97297501 provided with regulator External Gate Power Supply External Gate Power Supply if used 94809301 10 AWG TwistedPair 2 Twists in 18 AWG TwistedPair 2 Twists in 0 677909 N m 6 lb in ...

Страница 6: ...isting UDC PMI cable RCV Fiber optic receive port The Drive Comm transmit port on the 1756 DMD30 ControlLogix Drive Module METER PORTS Four analog outputs for the monitor of internal registers Analog meters or analog inputs of a monitoring device 14 22 AWG twisted pair 2 twists per inch ARM FDBK Voltage Current and Phasing feedback Scaling Module Current Transformers and Phasing Transformer Cbl Ar...

Страница 7: ...WD GATES Armature Forward Gates Four forward gate outputs to provide gate signals for up to four power modules All four outputs are identical Cable Round Style Connector Fwd Gates SD3K CBLFWDPM060 5 foot length SD3K CBLFWDPM120 10 foot length SD3K CBLFWDPM180 15 foot length SD3K CBLFWDPM240 20 foot length 97305100 to view drawing for additional lengths REV GATES Armature Reverse Gates Four reverse...

Страница 8: ...of the LED COMM OK Drive Comm is active and synchronized FDBK OK The SD3000 Plus is receiving feedback from the resolver and no resolver feedback faults have been detected If the LED is off one of the following faults may have occurred Feedback Loss Fault armature voltage has exceeded 40 of the rated value and speed feedback has been less than 5 of motor base speed Broken Wire Fault a resolver sin...

Страница 9: ...ControlLogix Drive Module User Manual All Types 1756 UM522 1756 DMD30 Reference Manual ControlLogix Drive Module SD3000 Interface 1756 RM088 POWER MODULES FWD MODULE REV MODULE TB Recommended Power Modules 356405 Cxx 356406 Cxx 356407 Cxx SD 3K CBLCPLR 072 Make as short as possible Do not route with power leads TB Recommended SD 3K CBLCPLR 072 Make as short as possible Do not route with power lead...

Страница 10: ...x TB Recommended SD3000 PLUS Retrofit of Non Rockwell Power Module S6R SD3K CBLCPLR072 Make as short as possible Do not route with power leads Gate Coupler Assembly SD3K GATMDLHIGH 9732017 to view drawing SD3K CBLREVPMxxx TB Recommended SD3K CBLCPLR072 Make as short as possible Do not route with power leads POWER MODULE FWD REV FWD GATES SD3000 PLUS REV GATES Drawing 97329101 Drawing 97329101 Draw...

Страница 11: ...des DSSD3P IN001B EN P December 2004 Copyright 2005 Rockwell Automation All rights reserved Printed in the U S A Note Dierikon power module gate coupling boards are compatible with the SD3000 Plus Gate Scaling Module Part No 97331001 POWER MODULE FWD REV SD3K CBLREVELCxxx SD3K CBLFWDELCxxx SD3K CBLGSCLIRxxx SD3000 PLUS Retrofit of Reliance Power Module S6R With Elco rectangular style gate connecto...

Страница 12: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: