Publication 2706-IN006E-EN-P
InView Marquee Message Display
15
4.
If the sign is to be used with serial communications, remove one
or both of the hole plugs from the lowest holes on the right end
of the sign case. Otherwise, proceed to Step 6.
9.
Connect the incoming serial wires per pinout.
TB1 can be used for incoming RS-485 or RS-232 serial
connection. They cannot be connected at the same time.
RS-485 is recommended to reduce undesirable electrical
interference.
Power connection
LINE 1
GR
OUND
LINE 2 OR
NEUTRAL
LINE 1
GR
OUND
LINE 2 OR
NEUTRAL
208 - 240 VAC INPUT
Neutral
(Line 2):
Line
(Hot)
Ground
GREEN
w/
Serial device hole
plug/opening
Right-end view
TIP
TB1 can be used for incoming serial connection for
RS-232 or RS-485. The full pinout diagram is shown
below:
TB1 - Full
1. GND
5. RS-485(+)
2. +5V
6. RS-485(-)
3. RS-232 TX
7. NC
4. RS-232 RX
8. SHIELD
TB1 - RS-485
1. NC
5. RS-485(+)
2. NC
6. RS-485(-)
3. NC
7. NC
4. NC
8. SHIELD
Содержание 2706-P4 Series
Страница 41: ...Publication 2706 IN006E MU P 42 Afficheur de messages InView...
Страница 62: ...Publikation 2706 IN006E MU P Laufschriftanzeige InView 63...
Страница 63: ...Publikation 2706 IN006E MU P 64 Laufschriftanzeige InView...
Страница 83: ...Pubblicazione 2706 IN006E MU P 82 Cartellonistica InView...
Страница 103: ...Publicaci n 2706 IN006E MU P 102 Pantalla para exhibici n de mensajes InView...
Страница 123: ...Publica o 2706 IN006E MU P 122 Displays de Mensagens InView Marquee...
Страница 124: ......