Integrated Access Controller  – Installation manual  

All rights reserved. © AAT HOLDING S.A.

 

 

8. Sound and light indication 

 

 
 
 
 
 

 
 
 
 

 
 
 

 

9. Master setting 

Enter Master Operation Mode. It will return to normal mode if there is no right 
Master PIN input in 5 seconds. After input of right master PIN, it will also return 

to normal mode if there is no valid operation in 30 seconds. Press “#” to confirm 
the input number, return to previous menu by press “*”, the logo light will indi-

cate the operation mode.  
 

Note that to undertake the following programming, the master user must be 
logged in. 
 

 

Содержание KZC-800-H

Страница 1: ...Installation Manual INTEGRATED ACCESS CONTROLERS PROXIMITY CARD READERS KZC 800 U H KZC 800 M KZC 900 U H VERSION 1 2 Update 29 12 2014...

Страница 2: ...s 1 door supports up to 2000 users in total each user have one card and one PIN PIN 1234 as de fault should be change for normal using The access control unit supports 1 master code one manager add ca...

Страница 3: ...nd green LED display the working status 12 24V DC Operating Voltage 12 24V DC User Capacity 2 000 with card and PIN 1234 default PIN Keypad 12 keys 3 x 4 digits and 2 x 6 digits KZ 900 Card Type EM HI...

Страница 4: ...ce where controller should be locate Drill 4 holes diameter 6mm rubber bungs on the wall for the screws and 1 hole 30 or 22mm for the cable as written on the sticker figure 1 Fix the metal product bra...

Страница 5: ...de is describe on next pages Wiring diagram Color Function Description Light green BELL_A Bell control output Pink BELL_B Bell control output Red 12V Supply power input 12 24V DC Black GND Supply powe...

Страница 6: ...Unlock when power on such as Electronic Controlling Lock smart lock etc Type B electronic lock Fail Safe lock Unlock when power off such as Electromagnetic Lock Electronic Bolt Lock etc 1N4004 Diode...

Страница 7: ...nly and set 2 10 for opening the door by multi cards 4 5 Toggle Mode In normal mode every time a valid card tag read or PIN input the relay will op erate for the pre set relay pulse time In Toggle mod...

Страница 8: ...unit s buzzer and the external alarm will operate 5 3 Anti duress alarm When read duress card input 8 digits duress PIN the corresponding lock will open at the same time the external alarm will opera...

Страница 9: ...to normal mode if there is no right Master PIN input in 5 seconds After input of right master PIN it will also return to normal mode if there is no valid operation in 30 seconds Press to confirm the i...

Страница 10: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 10 9 1 Basic Operation 5 s 50 ms...

Страница 11: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 11 In 10 minutes if there s 10 times invalid card or wrong password the device will lock on for 10 minutes...

Страница 12: ...r the close in close state the first press key is just to start the keyboard light no any function 10 times consecutive errors including enter an invalid master code user password or anti duress or in...

Страница 13: ...evel is low the Buzzer will beep after 30 seconds or BZ level rising the Buzzer will back to normal When the access controller worked as reader both card number and keypad transmits in Wiegand format...

Страница 14: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 14...

Страница 15: ...7 10000111 8 01111000 9 01101001 01011010 0 11110000 01001011 11 2 Standalone for Single door In this mode the access host uses can open the door by valid card or PIN it supports connecting external c...

Страница 16: ......

Отзывы: