Parameter or function name 

Parameter value  

or function description 

Buffer capacity 

 

- Card buffer 

   20 000 (2 000 in standalone mode) 

 - Event buffer 
 - Alarm buffer 

   50 000  
   20 000 

Electrical parameter 

 

- Supply power 

   12 VDC 

- Current load 

   < 110 mA 

anti-static capability

:

 

   YES 

Environment parameter 

 

- Environment 

 

 

   For indoor installation only 

- Working Temperature 

    From+2

°

C to 55

°

- Relative Humidity 

   0% - 95% 

- Size (L x W X H) 

   150 x 88 x 25 mm 

Communication ports 

 

For connection with KaDe Premium Plus 

   - TCP 

For additional module connection 

   - RS485 

Readers and Cards 

 

- Integrated reader 

   For UNIQUE card, read range 5 - 15 cm (U) 
   For MIFARE card, red range 2– 5 cm (M) 

- External (for two way control) 

   26 bit Wiegand output format 

- Card format  

   ISO UNIQUE (125 kHz) 
   MIFARE (14443A) (13,56 MHz) 

- External reader keypad PIN format 

   4-bits, without buffering 

Inputs 

 

- Door contact input 

   NO / NC (NO - default) 

- Exit button input 

   NO / NC (NO - default) 

- PIR input 

   NO / NC (NO - default) 

Relay output 

 

- Strike (lock) control 

    Relay DC 12V 3A (NO / C / NC) 

- Alarm control 

    Relay DC 12V 3A (NO / C / NC) 

- Bell control 

    NO/NC 

Access level parameter 

 

- Access level 

   200 

- Schedule 

   184 

- Holiday 

   32 

Identification mode 

   Card, Card + PIN, PIN , Card or PIN 

Alarm relive 

   Automatic or manually by operator 

2. KZ-1000-IP Controller Technical Data 

Содержание KZ-1000-IP-M

Страница 1: ...Installation Manual INTEGRATED ACCESS CONTROLLER KZ 1000 IP U KZ 1000 IP M VERSION 1 0...

Страница 2: ...served AAT HOLDING S A 2 1 Introduction 3 2 Controller technical data 5 3 Controller wiring diagram 6 4 Controller installation 8 5 Management in standalone mode 9 6 Programming codes table 14 7 Manag...

Страница 3: ...ontrol Recommended supply power type AWZ 200 plus 7Ah battery It s possibility to set one from four identification mode Card only default mode PIN only Card or PIN Card PIN KZ 1000 IP can work in stan...

Страница 4: ...85 for connection with additional modules Supply Power connectors 12V 110 mA Lock control relay output Alarm relay output Bell control output from keypad key LED located on front panel upper left Blue...

Страница 5: ...m Plus TCP For additional module connection RS485 Readers and Cards Integrated reader For UNIQUE card read range 5 15 cm U For MIFARE card red range 2 5 cm M External for two way control 26 bit Wiegan...

Страница 6: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 6...

Страница 7: ...UZ Blue Door contact SW Yellow Ground RD GND Black Exit button AN Purple PIR sensor input ALM Brown Ground RD GND GND RS485 port signal 485 Gray RS485 port signal 485 Orange 12V Red Controller supply...

Страница 8: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 8 Installation instruction...

Страница 9: ...on is already stored card Five beeps card with this number is already added Optical indicator LED Blue LED Power on Green LED confirmation of the validity of the operation Orange LED flashing waiting...

Страница 10: ...programming mode enter the code 13 then Code 00 when you want to disable the monitoring of the sensor code 01 to activate monitoring When a tamper alarm is activated an attempt to remove the unit from...

Страница 11: ...lue from 00 to 99 seconds default 3 sec This is the time by which when a valid card or code is used the door will be unlocked After entering the programming mode enter the code identification mode 221...

Страница 12: ...nter the PIN again Repeat the operation for subsequent reading cards with PIN codes After each added card reader generate a single beep Read the card will be cred ited automatically generated ID numbe...

Страница 13: ...After adding a new administrator PIN code controller will generate a single beep and automatically exits the programming mode NOTE The default master code 000000 is mandatory to change after the firs...

Страница 14: ...fault Alarm input line parameters Alarm action delay Alarm relay output 161 01 type NO 00 type NC 162 00 99 sec 0 sec default 163 1 RL1 2 RL2 3 RL1 2 4 no out Access mode setup Card only 221 Card PIN...

Страница 15: ...ntroller must be installed within a protected space at a temperature of above 2 C and normal humidity Controllers in the system should be located so that the minimum distance from cables and high volt...

Страница 16: ......

Отзывы: