Programming the controller in network mode 

 
 

Controller KZ-1000-IP can operate in stand-alone mode or network mode 

under the supervisory software installed on computer. 
It is also possible operation of the controller in the "off-line" after programming 

with the supervisory software when the controller is connected through an IP 
port. 

Supervisory program on PC gives a much more powerful programming and mon-
itoring system based on controllers KZ-1000-IP. A detailed description of control-

ler programming in network mode refer to the instructions for the program 

KaDe Premium Plus 

and the help files dynamically displayed on the operator 

panel.

 

 

 

General guidelines for the installation of the controller 

 

 

Before installing the controller should be familiar with this manual. 

 

Installation of the controller can be performed only by qualified personnel 
with the appropriate certified to install and service this type of equipment. 

 

The controller must be installed within a protected space at a temperature 
of above + 2 ° C and normal humidity. 

 

Controllers in the system should be located so that the minimum distance 
from cables and high-voltage devices and other devices that generate elec-

trical noise was 2 m. The minimum distance from telephone lines should be 
1 m, and from 8 m transmitting devices. 

 

As the housing of the controller is equipped with a tamper sensor so care 
must be taken to the surface for mounting the controller housing it was 

hard and smooth. 

 

The controller should be powered from a linear power supply with backup 
battery with parameters. 12 VDC, 1A. This takes into account the possible 
supply of an electric lock with the same power supply. In this case the at 

the lock terminals should be installed diode 1N4004 in the reverse direction. 

 

Wiring and performing any work on the internal components of the control-
ler while power is categorically prohibited. This can lead to damage. 

 

Before connecting the controller to the power supply must perform all the 
necessary connections in accordance with the instructions. 

 

The connection to the computer is to be implemented using the IP port. 

 

Each controller must be set to a different IP address. 

Содержание KZ-1000-IP-M

Страница 1: ...Installation Manual INTEGRATED ACCESS CONTROLLER KZ 1000 IP U KZ 1000 IP M VERSION 1 0...

Страница 2: ...served AAT HOLDING S A 2 1 Introduction 3 2 Controller technical data 5 3 Controller wiring diagram 6 4 Controller installation 8 5 Management in standalone mode 9 6 Programming codes table 14 7 Manag...

Страница 3: ...ontrol Recommended supply power type AWZ 200 plus 7Ah battery It s possibility to set one from four identification mode Card only default mode PIN only Card or PIN Card PIN KZ 1000 IP can work in stan...

Страница 4: ...85 for connection with additional modules Supply Power connectors 12V 110 mA Lock control relay output Alarm relay output Bell control output from keypad key LED located on front panel upper left Blue...

Страница 5: ...m Plus TCP For additional module connection RS485 Readers and Cards Integrated reader For UNIQUE card read range 5 15 cm U For MIFARE card red range 2 5 cm M External for two way control 26 bit Wiegan...

Страница 6: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 6...

Страница 7: ...UZ Blue Door contact SW Yellow Ground RD GND Black Exit button AN Purple PIR sensor input ALM Brown Ground RD GND GND RS485 port signal 485 Gray RS485 port signal 485 Orange 12V Red Controller supply...

Страница 8: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 8 Installation instruction...

Страница 9: ...on is already stored card Five beeps card with this number is already added Optical indicator LED Blue LED Power on Green LED confirmation of the validity of the operation Orange LED flashing waiting...

Страница 10: ...programming mode enter the code 13 then Code 00 when you want to disable the monitoring of the sensor code 01 to activate monitoring When a tamper alarm is activated an attempt to remove the unit from...

Страница 11: ...lue from 00 to 99 seconds default 3 sec This is the time by which when a valid card or code is used the door will be unlocked After entering the programming mode enter the code identification mode 221...

Страница 12: ...nter the PIN again Repeat the operation for subsequent reading cards with PIN codes After each added card reader generate a single beep Read the card will be cred ited automatically generated ID numbe...

Страница 13: ...After adding a new administrator PIN code controller will generate a single beep and automatically exits the programming mode NOTE The default master code 000000 is mandatory to change after the firs...

Страница 14: ...fault Alarm input line parameters Alarm action delay Alarm relay output 161 01 type NO 00 type NC 162 00 99 sec 0 sec default 163 1 RL1 2 RL2 3 RL1 2 4 no out Access mode setup Card only 221 Card PIN...

Страница 15: ...ntroller must be installed within a protected space at a temperature of above 2 C and normal humidity Controllers in the system should be located so that the minimum distance from cables and high volt...

Страница 16: ......

Отзывы: