Electromagnetic locks and mounting brackets –
Installation manual
6
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
4. ELECTROMAGNETIC LOCKS
’
ELECTRICAL CONNECTIONS
Electrical connection schemes of KaDe electromagnetic locks are shown in the pictures below.
5. KADE LOCKS AND COMPATIBLE BRACKETS LIST
The table below shows available electromagnetic locks and compatible mounting brackets in the offer.
Electromagnetic lock
„
BZLC
”
type bracket
„
L
”
type bracket
„
ZL
”
type bracket
KDA
-
LOCK180Z
-
II
-
KDA
-
BL180
-
II
KDA
-
BZL180
-
II
KDA
-
LOCK280DZC
-
II
KDA
-
BZLC280
-
II
KDA
-
BL280
-
II
KDA
-
BZL280
-
II
KDA
-
LOCK350DZC
-
KDA
-
BL350
KDA
-
BZL350
KDA
-
LOCK500DZC
-
II
-
KDA
-
BL500
-
II
KDA
-
BZL
-
500
-
II
4.2. KDA
-
LOCK280DZC
-
II/350DZC/500DZC
-
II
Lock state sensor (Hallotron sensor)
Use NO & COM for normally open
circuit, and NC & COM for normally
closed circuit.
Power supply
12 VDC or
24 VDC
Power supply voltage
socket—connection
from magnet coil
Connection module
Door state sensor
’
s localization in lock
Magnet localization
Metal plate
Delay setting
0 s 9 s
280DZC
-
II, 350DZC,
500DZC
-
II only
Hallotron sensor socket
4.1. KDA
-
LOCK180Z
-
II
Red
Black
White
White
+12 VDC
GND
Lock state
sensor
(Hallotron sensor)