13
4.8 Technical data
WARNING - The approved total weight may not be exceeded because it can lead to malfunction
or cause an overload of the c-max U2!
i
NOTE – Observe the technical data.
Technology
c-max U2 C1612
Measurements
See chapter “Dimensional drawing”
Weight
Climbing unit c-max U2 incl. both arm rests = 30.9 kg
Battery pack = 4.0 kg, Total weight without battery pack = 30.9 kg
Total weight approved
194 kg
Max. weight of the person (max. load)
160 kg
Climbing speed
1)
9 - 23 steps / minute (continuously adjustable)
Range with one charge of the batteries -
with an average load of 75 kg
1)
approx. 25 floors (corresponds to approx. 375 steps)
Range with one charge of the batteries -
with a maximum load
1)
approx. 9 floors (corresponds to approx. 135 steps)
Maximum height of step
210 / 225 mm (extended climbing height)
Minimum depth of step
2)
140 mm
Necessary step width (straight stairs)
Width c-max + 100 mm
Minimum platform size (U-shaped stairs)
1350 x 1350 mm
Minimum radius of spiral staircases
1350 mm
Minimum depth of step (spiral staircases)
2)
140 mm
Maximum gradient of the stairs
60.3°
Tilt stability
in driving direction 3.7 ° / against driving direction 2.7 °
Batteries
2 x 12 V / 5 Ah (gas-proof)
Direct current motor
24 V / 275 W
Operating force UP/DOWN switch
3-8 N
Direct operating force
max. 350 N whilst climbing upstairs / downwards (Chapter 8.5)
Noise information
< 67 dB
Storing/operating temperature: device
-40° C to +65° C / -25° C to +50° C
Storing/operating temperature: batteries
-20° C to +65° C
(3)
/ -25° C to +50° C
(3)
Charging temperature: batteries
0° C to +40° C
Height operating range
(NHN, normal height null)
< 3.000 m above sea level
Vibration information
The weighted RMS value of acceleration the upper body is exposed to lies
typically below 2.5 m/s
2
.
Type label with serial number
Left on the power unit and the rear of the user manual
IP protection class
IPX4 protection class: Protection against splash water from all sides
Classification according to ISO 7176-28:2012
Type C (table 1 of annex A)
1) The climbing speed as well as the range with one charge of the batteries is reduced if the ComfortStep is activated.
The range also depends on the weight of the person seated.
2) Never use the stair climber to climb stairs with too little depth because it is no longer possible for the main wheels to touch the steps safely.
3) Temperatures below 0°C will reduce the performance of the battery pack, therefore we recommend a storage temperature of at least 0°C.