Page 14 American Access Systems / Security Brands, Inc.
a. To program the Event Input as Remote Open enter the following:
(MASTER CODE) + 9 (*current mode) + 3 + (*Relay to Activate)
a. To PROGRAM the Event Input as NIGHT LIGHT enter the following;
(MASTER CODE) + 9 (*current mode) + 4
a. To DISABLE the Event Input enter the following;
(MASTER CODE) + 9 (*current mode) + 0
*Current Mode *Relay to Activate Single beep = Remote Inactive Mode Enabled. 1 = Relay A
Double beep = Arming Circuit Mode Enabled. 2 = Relay B
Triple beep = Remote Open Mode Enabled
GOOD TONE Only = Event Input Disabled
After you have selected Sub-Mode 9, the unit will respond with tones as described above. This
tells you the current mode the event input is programmed as (See *Current Mode above). If you do not wish to toggle
the state, enter # to exit. If you are programming the event input as a
Remote Open input, you will be prompted for which relay to activate on an event. Enter the
correct relay as stated above (* + Relay to activate).
Sub-Mode 0 (Erase all codes)
• To erase all access & function codes, (except the MASTER code), enter the following:
(MASTER CODE) + 0 + (MASTER CODE)
• When the sequence is entered correctly, the LED’s will flash several times and the unit will generate a GOOD
TONE when the memory has been cleared. If the above sequence is not validated by the unit, you will
receive
an ERROR TONE and immediately be exited from the program mode.
IMPORTANT NOTE: It should not generally be necessary to erase all the codes from memory unless
the codes are lost/forgotten and are occupying needed memory. A good code log and mainte-
nance of access codes should prevent erasure of all codes from ever needing to be done.
Troubleshooting
Pressing call button at the gate results in 3
rings and then ERROR TONE
Units are communicating but no phone line is
present. Make sure the Telco phone line is correctly
connected, and that bypass switch is in normal. If it
is supposed to be in PBX make sure it is.
Voice connection is noisy
Check all connections to make sure they are tight. If on
solar power, try turning off the charger to see if signal is
clearer.
Microphone and/or speaker volume too low.
Adjust the MIC and /or SPEAKER pots on circuit board to
desired levels. A maximum of 5 turns clockwise is allowed.
If These Do Not Work, There Are No Other Adjustments. Return the unit or contact Technical Support