background image

Page 11 American Access Systems / Security Brands, Inc.

 

• Release SETUP button and enter “# * #”. The unit will sound a GOOD TONE.

 

• Enter 1 2 5 1 on the keypad. The unit will flash the LED’s several times and then again will begin to beep 

 

 repeatedly.

 

• Press and release SETUP button

 

• The PhoneLink is now completely reset to factory defaults.

Idle Mode

The Idle mode is the normal operating mode. When in the idle mode the unit is ready to accept data from the 
keypad. You will have approximately 4 seconds between key presses. If time is exceeded, you will receive an ERROR 
TONE.

The Program Mode

The Program Mode is the mode of operation you use to enter, delete, or change access codes or set specific features 
of the unit.
 

• The Program Mode is accessed by entering the “MASTER CODE” from the keypad. You will receive a GOOD 

 

  TONE and the yellow LED will light, indicating that you are in the Program Mode. You then will have 

 

  approximately 30 seconds between key presses. If this time is exceeded, you will receive an ERROR and be 

 

  exited from the program mode.

The * and # Keys

The * and # keys serve specific functions while in the Idle or Program mode. The “*” key is always the clear key and 
a double beep will be heard any time the “*” is pressed. You should use this key if you make an entry error. The # key 
also serves as the clear key in the idle mode. In the program mode however, the # key serves as the exit key.

Programming the Gate

To access the program mode, enter the MASTER CODE. If the MASTER code is valid, the yellow LED will come on and 
the individual will be prompted with a GOOD TONE to enter a number corresponding to a SUB-MODE. Remember: 
MASTER Code will not activate control relay. (MASTER CODE) + (Number corresponding to Sub-Mode).
Once in the program mode, the individual will have 30 seconds between key presses or the
unit will ERROR and exit the program mode. A person desiring to exit the program mode may
do so by simply pressing the # key at any time. There are 10 different SUB-MODES to choose
from. They are as follows:

SUB-MODE Description

1

Program Access Codes (Relay A)

2

Delete Codes

3

Change MASTER Code

4

Set Sleep Code Latch Code and/or Call Forwarding

5

Set One Shot Code

6

Set Relay Output Time

7

Program Access Codes (Relay B)

8

Enable / Disable “3 Strikes-You’re Out”

9

Program Event Input

0

Erase Memory

Sub-Mode 1 (Program Relay A Access Codes)

 

• To program new Relay A access codes enter the following:

(MASTER CODE) + 1 + (NEW CODE) + (NEXT NEW CODE) etc, then ( # ) to exit program mode

Select any 4-digit code you wish. If you receive an ERROR TONE after entry, the new code is already being used. 
Select another 4-digit code. The unit will respond with a GOOD TONE with the acceptance of each new Relay 
A code. You may continue entering Relay A codes until you finish (Press #), or the memory becomes full. You will 
automatically be exited from the program mode if the memory reaches capacity. When memory is full, you will not 
be able to enter this Sub-Mode and will receive an ERROR if entry is attempted.

Sub-Mode 2 (Delete Codes)

 

• To delete codes enter the following;

(MASTER CODE) + 2 + (CODE TO BE DELETED)

You can delete any Access or Function code that you wish with the exception of the MASTER CODE. If the code you 
wish to delete is not found in memory, the unit will respond with an ERROR and wait for another code to be entered. 
A GOOD TONE will be sounded once the code has been found and deleted. You may continue deleting codes until 
you finish (Press #).

Содержание PhoneLink 500

Страница 1: ...Phonelink Access Control Station Installation and Operating Manual www americanaccess com Your Partner in Access Control ...

Страница 2: ...ntercom Audio Mode 9 Indoor Command Code s Reference 9 Access and Function Codes 10 Good Tones and Error Tones 10 Resetting the Unit 10 Master Reset 10 Unit Reset 10 Idle Mode 11 The Program Mode 11 The and Keys 11 Programming the Gate 11 Sub Mode 1 Program Relay A Access Codes 11 Sub Mode 2 Delete Codes 11 Sub Mode 3 Change MASTER Code 12 Sub Mode 4 Set Sleep Code Latch Code and or Call Forwardin...

Страница 3: ...sive This is the only Warranty we offer on this product and it sets forth all of our responsibilities regarding your AAS product There are no other express Warranties State Law Rights This Warranty gives you specific legal rights and you may have other rights which vary from State to State FCC Requirements This equipment complies with Part 68 of the Federal Communications Commission Rules On the i...

Страница 4: ...ne lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Notice The Ringer Equivalency Number REN assigned to each terminal device provides an indica...

Страница 5: ...ow the instructions in this manual carefully to prevent problems during installation and programming 6 7 American Access Systems cannot guarantee compatibly with all telephones and accessories answering machines caller ID etc Installation Proper wire size is necessary for a good and trouble free installation Follow the tables below for your installation DC Power Wire Size Distance in feet AC Power...

Страница 6: ...e to Relay B Wiring the Station 12 The PhoneLink is designed to go inline with the incoming phone line See page 9 At the Telephone Company Telco box on the side of the building disconnect the connections between the phone company and the house 13 Run 4 conductor 22 AWG twisted shielded wires between the Telco box and the PhoneLink unit Connect two wires between the Telco box phone company tip and ...

Страница 7: ...uit Board PHONE COMPANY HOUSE PHONES T I P R I N G T I P R I N G N O COM N C N O COM N C RELAY A RELAY B EVENT INPUT Power TELCO BOX Located on side of house Customer Side Only Connection Screws Remove house telephone wires from Connection Screws and connect here Red Green 3000 ft Max Distance Earth Ground Board Bypass Switch Telco Box Phone Company Phone Company To Phones House Phones PhoneLink 5...

Страница 8: ...Page 8 American Access Systems Security Brands Inc BOARD LAYOUT ...

Страница 9: ...es tablish the data mode The key cannot be used to get back to data mode in the same fashion that is used to switch between call waiting and talking to the gate Intercom Audio Mode Once the data mode communication is established the phone is connected to the unit in data mode only It is now possible to send Commands to control the gate from the telephone handset Again audio is not present To estab...

Страница 10: ... of the relay s activation period The yellow LED illuminates while the unit is in the program mode During memory erasure or setup the LED s will flash Resetting the Unit Your unit provides two very distinct types of resets a Master Reset and a Unit Reset It is important to understand when to use each A MASTER Reset should be done in the event that you lose or forget your MASTER code or if the unit...

Страница 11: ...emember MASTER Code will not activate control relay MASTER CODE Number corresponding to Sub Mode Once in the program mode the individual will have 30 seconds between key presses or the unit will ERROR and exit the program mode A person desiring to exit the program mode may do so by simply pressing the key at any time There are 10 different SUB MODES to choose from They are as follows SUB MODE Desc...

Страница 12: ...d position The latch code is useful in applications when the gate is desired to hold open If the operator s close circuit is controlled by loops timers etc they will be overridden by the latched state of the relay and the gate will hold open An OPEN OVERRIDE circuit must exist in the operator equipment in order to utilize this function If your gate cycles when this code is entered your operator is...

Страница 13: ...correct codes are entered successively within a 3 minute period When this occurs the LED s will flash and a high pitched alarm will be generated from the unit for 30 seconds The unit will then shutdown for 1 minute To toggle the 3 strikes you re out feature enter the following MASTER CODE 8 current state MASTER CODE Current state single beep 3 strikes enabled double beep 3 strikes disabled After y...

Страница 14: ...ng MASTER CODE 0 MASTER CODE When the sequence is entered correctly the LED s will flash several times and the unit will generate a GOOD TONE when the memory has been cleared If the above sequence is not validated by the unit you will receive an ERROR TONE and immediately be exited from the program mode IMPORTANT NOTE It should not generally be necessary to erase all the codes from memory unless t...

Страница 15: ...ur Technicians assist you E Mail customerservice securitybrandsinc com Technical Support 303 799 9757 Technical support is available free of charge Hours are 8 00 a m to 4 30 p m MST If you call please have your Model and Serial Number to help our Technicians assist you E Mail techsupport securitybrandsinc com 1675 West Yale Ave Englewood CO 80110 phone 303 799 9757 fax 303 799 9756 sales security...

Страница 16: ...Page 16 American Access Systems Security Brands Inc Notes Use this space to keep a record of Access Codes and the MASTER Code ...

Страница 17: ...Page 17 American Access Systems Security Brands Inc Notes ...

Страница 18: ... Your partner in access control www securitybrandsinc com SECURITY BRANDS INC ...

Отзывы: