background image

10

Aarrow Ecoburn Wood & Multifuel Stoves

INSTALLATION

FITTING THE FLUE OUTLET AND
HOT PLATE

The flue outlet spigot is found packed inside the
appliance. The hot plate (blanking plate) is supplied
fitted to the top opening and is removed by turning
clockwise (as is the flue outlet).

Smear a very thin layer of fire cement on the faces
of the flue outlet and the blanking plate. Fit the out-
let to the appliance in the desired position .

Lock into place by rotating anti-clockwise and
tighten by tapping with a block of wood and mallet
from the inside of the appliance. Similarly, fit the
blanking plate to the unused opening. Clean off any
surplus fire cement.

Place appliance on the hearth and make sure that it
is level and does not rock. The Solution range of
stoves are fitted with adjustment cam on both rear
legs, see page 14 for details.

Connect the chimney ensuring all joints are sealed
with fire cement.

Fig. 1. Flue and Spigot Fitting

FLUES AND CHIMNEYS

Please remember that chimney draught is
dependent on four main factors:

• Flue gas temperature.
• Flue height.
• Flue size.
• Flue terminal.

The stove must be connected to a suitable and
efficient flue that provides a good up draught to
safely take the products of combustion (fumes)
from the stove outlet to the outside air. To ensure a
good up draught it is important that the flue gases
are kept warm and that the flue size suits the stove.  

The termination of the outlet at the top of the flue
also needs to comply with the Building
Regulations. The minimum effective height of the
flue must be at least 4.5 metres from the top of the
stove to the top of the flue outlet. When warm the
flue draught should be between 0.1 and 0.2 mb.

A chimney may comply with the regulations but
still be subject to down draught and similar
problems. A chimney terminating above the ridge
level is generally less likely to suffer such
problems.

If a new chimney is being provided it should fully
comply with the relevant Building Regulations that
specify the requirements for solid fuel burning
installations. Suitable types of chimney include the
following.

Masonry chimney

built with clay or concrete

liners, or a chimney block system meeting Building
Regulations. These types of chimney should be
installed in accordance with the Building
Regulations and BS 6461: Part 1.

Factory made insulated chimney

complying

with BS 4543: Part 2 (often called "Class 1
prefabricated metal chimney"). These types of
chimney should be installed in accordance with the
Building Regulations and BS 7566: Parts 1 to 4.

*NOTE

THE FLUE PIPE MUST BE FITTED INSIDE THE OUTLET SPIGOT

FAILURE TO DO SO COULD RESULT IN THE SPILLAGE OF

CONDENSATION ECT. RUNNING DOWN THE FLUE.

Содержание Ecoburn 11 Multifuel

Страница 1: ...Wood Multifuel Model Range Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Ecoburn 7 Multifuel Rev 6 October 2006 AFS1221 BK043...

Страница 2: ...n the reliability of our product that we offer a Lifetime Guarantee Should you have any questions about our Ecoburn Stoves that are not covered in this manual please contact the Aarrow dealer in your...

Страница 3: ...Annual Maintenance 21 Summer Storage Non Usage 21 Door Adjustment 21 Dissassemble Airwash 22 Fuel Retaining Bars Inspection 22 Fire Door Glass 23 Service Record 24 OPERATING INSTRUCTIONS Fuel Types 25...

Страница 4: ...ED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPARE PARTS...

Страница 5: ...fire If not properly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Aarrow Fires produce a var...

Страница 6: ...Rear liner s 7 Side liners 2 N A ECB 7 Wood 1 5 2 2 ECB 7 Multifuel N A ECB 5 Wood 1 4 2 7 1 5 2 ECB 9 Wood ECB 9 Multifuel 2 1 4 1 5 1 4 1 5 1 Grate bars 1 1 2 Wood burning tray ECB 11 Multifuel ECB...

Страница 7: ...grate bar support 11 Fire door han dle Nickel Plated 1 1 1 9 Comb assembly consisting of comb comb extension bar 1 N A N A 1 N A 1 1 1 N A 1 1 1 15 Stove Mitten 2 1 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 N A N...

Страница 8: ...f canopy to the tip of the handle The model and Serial Number of your stove can be found stamped into the casing centrally just below the bottom edge of the fire door aperture 522 522 558 558 476 476...

Страница 9: ...tion HEARTH The stove should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth shoul...

Страница 10: ...stove outlet to the outside air To ensure a good up draught it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the top of the flu...

Страница 11: ...ent J of the Building Regulations for England and Wales is available from The Stationery Book shops and can also be viewed at the ODPM website at www safety odpm gov uk bregs brads htm Details on the...

Страница 12: ...12 Aarrow Ecoburn Wood Mutifuel Stoves INSTALLATION Fig 2 A Typical Rear Flue Layout...

Страница 13: ...TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 A is minimum clearance for non insulated flu...

Страница 14: ...r the other rear leg WOOD STOVE VERSION WOOD TRAY The wood burning tray should come fitted in your stove if not please follow these instructions Fully open the fire door and remove the two round fuel...

Страница 15: ...e upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seated on the high section of the comb See fig 8 for the assembled grate layout GR...

Страница 16: ...small liner s into the back of the fire Insert side liner panels See Fig 10 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the side...

Страница 17: ...for individual heating systems should be carried out by a qualified heating engineer In many cases your supplier will be able to offer advice and assistance Direct Systems Stainless steel boilers eit...

Страница 18: ...pipe from the expansion tank should be 28mm diameter copper Pipes in unheated spaces must be lagged FINAL CHECK Before handing over the installation to the customer it is strongly recommended that the...

Страница 19: ...e calculated natural draught gas appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an exis...

Страница 20: ...ch up spray as some paints interact This could ruin the finish and invalidate the guarantee DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions suc...

Страница 21: ...w air movement through the stove by opening the airwash and prinmary air inlet s controls to about half way open or leave the door ajar This will allow a free flow of air through the appliance thus pr...

Страница 22: ...et Lift outer cover free from body being careful not to damage the ends of each lug Fig 15 Slide off the spacer tube from the centre stud and retain for re assembly Unscrew the inner slider and clean...

Страница 23: ...lts on the inside of the door securing the retaining clips Carefully remove any pieces of broken glass and sealing gasket wearing suitable gloves Re place the gaskets and line them up in relation to t...

Страница 24: ...our Ecoburn stove that is not covered in this manual please contact your Aarrow Fires retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visi...

Страница 25: ...hurnacite Plus Centurion Maxibrite Extracite Pureheat Blazebrite Taybrite Sunbrite Doubles Singles Anthracite Large Nuts and Welsh Dry Steam Coal Large Small Nuts Approval does not cover the use of ot...

Страница 26: ...r long periods consequently more care in setting the controls and some familiarisation is necessary when burning anthracite Use the smallest size fuel Stovesse or Small Nuts Proceed as for manufacture...

Страница 27: ...housed in a cover plate and is located above the fire door Sliding the control knob to the right as far as it will go achieves the fully open position Sliding it to the left will shut off the air inle...

Страница 28: ...oburn stoves are supplied with a unique ash pan cover to prevent ash dust from being dispersed around the room when de ashing To remove the ashpan open the fire doors Slide the ashpan cover over the t...

Страница 29: ...cient fuel is placed in the firebox The controls are set correctly Excess draught is not present in the chimney Fire door is closed If the fire goes out with unburnt fuel left in the firebox increase...

Страница 30: ...AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AIB 0 AIB 0 AIB 8 AIB 8 AIB 9 AIB 9 AIB 10 AIB 10 Stove Gloves AFS997 AFS997 AFS997 AFS997 AFS997 AFS997 AFS997 AFS997 Floor Fixing Kit AFS 1135 AFS 1135 A...

Страница 31: ...urning tray ECB 11 Multifuel ECB 11 Wood 3 Stainless steel throat plate N A N A AFS 1197 AFS 1193 AFS 1193 AFS 1194 AFS 1194 AFS 009a AFS 009a AFS 010 AFS 010 AFGS 064 AFGS 064 AFS 009 AFS 009 AFS 120...

Страница 32: ...214 AFS 1215 AFS 1215 AFS 1010 AFS 1010 AFS 1010 AFS 1010 AFS 047 AFS 047 AFS 047 AFS 047 AFS 1205 AFS 1208 AFS 1208 AFS 1199 AFS 1199 AFS 1200 AFS 1200 12 Replacement Glass Gasket 15 Air Wash Assembl...

Страница 33: ...1 ECB 11 Multifuel ECB 11 Wood AFS 1218 AFS 1218 AFS 1219 AFS 1219 AFS 1306 AFS 1306 AFS 1306 AFS 1306 AFS 1121 AFS 1121 AFS 1121 AFS 1121 N A AFS 1226 N A AFS 1227 AFS 1021 AFS 1021 AFS 1021 19 Door...

Страница 34: ...hall be final If your appliance proves to be defective as a result of faulty materials or workmanship during the guarantee period we will repair or replace it FREE OF CHARGE as long as the fire has be...

Страница 35: ...other costs including labour incurred in its replacement Documentation must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage mis u...

Страница 36: ...ICKEL PLATED HANDLE ASH PAN COVER ADJUSTING FEET X 2 OPERATING TOOL CONVECTOR KIT FIXINGS X 4 OPERATING INSTRUCTIONS Model Serial No I ve checked it and it s O K Assembled by Checked by Date of Purcha...

Отзывы: