INTERLOCK SYSTEM
Nouveau fires are fitted with an "interlock" system.
A situation where the fire door is closed and the ash
door is open may lead to serious over firing which
could damage the appliance. Correct use of the
doors and interlock system will ensure that this
does not happen.
Operation is as follows:
A pivoted lug prevents closure of the fire door,
unless the ash door has been shut first. When the
fire door is shut the ash door knob can be turned
anti-clockwise by up to 95 degrees creating a
variable gap between the top of the ash door and the
body, through which primary combustion air can
enter the appliance.
Note: In order to turn the ash door knob
sufficiently for the catch to release and permit the
ash door to be opened fully THE FIRE DOOR
MUST BE OPENED FIRST.
MULTI - PURPOSE OPERATING
TOOL
Your Aarrow fire comes with a multi-purpose tool,
which is used for, riddling and setting multifuel
grate position and for emptying the ash pan. (Fig. 4)
Fig. 4
RIDDLING
Use the operating tool for setting the grate in the
coal burning position or the wood burning position.
This means that effective de-ashing (See page 13)
takes place, and also allows the grate to be set in the
coal burning or wood burning position, as
indicated on the right hand side of the appliance.
FIRE DOOR GLASS
If necessary the glass can be replaced as follows:
Step 1
The doors should be lifted off the hinges so
that the above operations can be carried out on a
workbench or similar level surface. This should be
done when the appliance is cold and unlit.
Step 2
Remove the glass retaining clips, remove
any pieces of broken glass.
Fig. 5a Putting gasket in place
Step 3
Replace the two retaining clips to hold the
glass in place.
Fig. 5b Glass, gasket & retaining clips
Step 4
Follow this procedure in reverse to fit
replacement door glass or gasket.
Fig. 5c Tightening glass clips
Nouveau 7 Multifuel Stoves
9
OPERATING INSTRUCTIONS