Nouveau 7 Multifuel Stoves

5

INTRODUCTION

SAFETY

A fireguard conforming to BS 8423: 2002 should
be used in the presence of children and old/or
infirm people. If the appliance is used with the fire
door open, a spark guard conforming to BS 3248
should be fitted.

Do not use aerosol sprays or any other flame
near the appliance under fire.
Do not fit an extractor fan in the same room as
the appliance.
Fire cement is caustic, hand and eye protection
should always be worn, prolonged contact with
the skin should be avoided.
Arada Ltd will not be responsible for any conse-
quential or incidental loss or injury      however
caused.

Before continuing any further with the installation
of this appliance please read the following guide to
manual handling.

•  Always obtain assistance when lifting the

appliance.

• When lifting always keep your back 

straight. Bend your legs not your back.

• Avoid twisting at the waist. It is better to

reposition your feet.

• Avoid upper body/top heavy bending. Do not     

lean forwards or sideways when
handling the fire.

• Always grip with the palms of your hands.

Do not use fingertips for support.

• Always keep the stove as close to the body as

possible. This will minimise the cantilever
action.

• Use gloves to provide additional grip.  

THE PRINCIPLE OF THE FIRE

Your Aarrow Fire is built to the highest standard of
craftsmanship using the best materials and the most
modern equipment available. It is a highly efficient
and sophisticated piece of machinery and when
properly installed and operated it should provide a
lifetime of heating satisfaction.

Safety

is the most important consideration when

installing your fire. If not properly installed and
operated a house fire may result. installation must
comply with the Building Regulations and conform
to all relevant fire safety standards.

Arada Ltd produce a variety of appliances   ranging
from units, which are traditional in style to stoves
which are modern in appearance, all        bristling
with "High Tech" features.

Model types include simple room heaters,
convectors, integral boiler models and inset units.
Your Aarrow Fire is constructed from either single
or twin wall steel strengthened where necessary.
Cast iron is used where appropriate for decorative
features.

All fire doors are fitted with special high
temperature ceramic glass panels through which
the fire can be viewed.

Multifuel stoves are fitted with a cast iron grate to
give full multifuel facility and positive de-ashing. 

All models except integral boiler models are lined
with firebricks or heat reflective panels which
ensure complete combustion and provide a good
heat store to even out fluctuations in burning.

An internal throat plate produces turbulence to
encourage secondary combustion and directs the
flue gas around the whole upper firebox before
allowing it to escape up the chimney.

On multifuel appliances the primary air for burning
enters the ash pit chamber beneath the grate,
controlled by the air inlet mechanism.  

Aarrow Fires are also fitted with an "air wash" so
called because it provides a curtain of high speed
preheated air behind the glass to help keep it clean
and to provide secondary air/over draught.

The provision of two inlets on all multifuel stoves
gives a wide range of primary air/secondary air,
under draught/over draught combinations. The
optimum settings will only be established by
experience in firing the appliance, and will depend
on type of fuel, the   position of the appliance in the
house, condition of chimney etc.

Содержание Nouveau 7

Страница 1: ...Nouveau 7 Multifuel Stove Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Nouveau 7 Multifuel Stove Rev 2 August 2004 AFS1120...

Страница 2: ...confident in the reliability of our product that we offer a Lifetime Guarantee Should you have any questions about our Nouveau Multifuel Stoves that are not covered in this manual please contact the...

Страница 3: ...ire 11 Over Firing 13 Cleaning Annual Maintenance 13 14 Accessories 15 INSTALLATION Page General Precautions 16 Handling 16 Hearth 16 Combustible Materials 16 Firebox Liner Panels 17 Throat Plate Insp...

Страница 4: ...E BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPARE...

Страница 5: ...rly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Arada Ltd produce a variety of appliances ra...

Страница 6: ...HECK LIST Part Description Visual Aid not to scale Nouveau 7 Multifuel 1 Grate Bars 5 2 Fuel Retainers 2 3 Throat Plate 1 4 Flue Spigot 1 5 5 Hot Plate 1 5 6 Ashpan 1 7 Operating Tool 1 8 Rear Liners...

Страница 7: ...DATA Nouveau 7 Multifuel Room Heater with Domestic Hot Water with add in boiler type 1 2 Max Output to Room kW Max Output to Water kW 4 4 3 2 6 4 Height mm 620 Width mm 476 Depth mm 365 Height to Cent...

Страница 8: ...ating the door knob if hot with operating tool anti clockwise to increase the the air inlet clockwise to reduce the air inlet or seal the ash door completely AARROW AIRWASH SYSTEM The air wash has an...

Страница 9: ...e tool which is used for riddling and setting multifuel grate position and for emptying the ash pan Fig 4 Fig 4 RIDDLING Use the operating tool for setting the grate in the coal burning position or th...

Страница 10: ...feet supplied Care should be taken whilst assembling the feet so as not to damage the painted surface of the fire The feet are positioned in each corner of the fire and fixed using the washers and scr...

Страница 11: ...reheat Blazebrite Taybrite Sunbrite Doubles Singles Anthracite Large Nuts and Welsh Dry Steam Coal Large Small Nuts Approval does not cover the use of other fuels either alone or mixed with the suitab...

Страница 12: ...he area is well ventilated during this time OVERNIGHT BURNING The appliance will bur overnight provided Sufficient fuel is placed in the firebox The controls are set correctly Excess draught is not pr...

Страница 13: ...and could easily start a fire or cause an injury Replace the ash pan and close ash door Close the fire down CLINKER The formation of clinker suggests that the unit is being over fired Any clinker for...

Страница 14: ...shut down period DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions such as burning at a low rate with damp wood or overnight burning the glass m...

Страница 15: ...erchangeable canopy Fig 7 Remove the front clamps Tilt the canopy as shown in stage 1 Engage the rear clips and pull fully forward Fit the front clamps and tighten Fit the required blanking plates as...

Страница 16: ...RTH The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should project...

Страница 17: ...to the front facing up The projecting lugs sit on top of the side liners The long centre tab on the back edge rests on the rear liners The shorter turn down tabs against the vertical face Replace the...

Страница 18: ...ing end marked L onto the low section of the comb The upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seated on the high section of...

Страница 19: ...umes from the stove outlet to the outside air To ensure a good updraught it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the t...

Страница 20: ...Document J of the Building Regulations for England and Wales is available from The Stationery Bookshops and can also be viewed at the ODPM website at www safety odpm gov uk bregs brads htm Details on...

Страница 21: ...Nouveau 7 Multifuel Stoves 21 INSTALLATION...

Страница 22: ...ATED FLUES TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 A is minimum clearance for non in...

Страница 23: ...n and calculations for individual heating systems should be carried out by a qualified heating engineer In many cases your supplier will be able to offer advice and assistance Direct Systems Stainless...

Страница 24: ...om the expansion tank should be 28mm diameter copper Pipes in unheated spaces must be lagged FINAL CHECK Before handing over the installation to the customer it is strongly recommended that the applia...

Страница 25: ...appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been refurbished...

Страница 26: ...2 AFS1019 AFS001 AFS010 AFS008 AFS058 AFS009 2 Throat Plate 3 Grate Bar Set 4 Hot Plate 5 Operating Tool 6 Ashpan 7 Flue Spigot Part Description Visual Aid not to scale Nouveau 7 Part No Pictures show...

Страница 27: ...35 AFS1077 9 Side Liner 10 Back Liner Set 11 Glass Replacement Kit Complete with Gasket 12 Glass Clips 13 Hinge kit Comprises 2 Hinges 4 Fixings Per Set 14 Airwash Part Description Visual Aid not to s...

Страница 28: ...040 AFS997 16 Main Doors Assembly Complete with Handle Glass Gaskets Clips and Seal 17 Nouveau Feet Including Fixings 18 Cast Fire Door Locking Assembly 19 Aarrow Fires Gauntlet Gloves Part Descriptio...

Страница 29: ...nnually by a qualified heating engineer The Manufacturers decision shall be final If your appliance proves to be defective as a result of faulty materials or workmanship during guarantee we will repai...

Страница 30: ...s manual please contact your Aarrow retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as they will complete the service record chart...

Страница 31: ...labour incurred in its replacement Documentation must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage misuse wear tear The use of...

Страница 32: ...al No I ve checked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on page 25 of this manual If...