HW © 2015 Aaronia AG, DE-54597 Strickscheid
11
Manual MagnoTRACKER
MagnoTRACKER
7.
Recommended Settings
You can find a recommended selection of settings depending on the measuring frequency
in the following table.
Frequency
Slide switch
X & Y
Control dial
x1
Control dial
x10
Control dial
x100
Control dial
x1000
10kHz
4
0
0
3
5
20kHz
4
0
5
3
1
30kHz
3
0
0
2
2
40kHz
3
0
2
2
1
50kHz
2
0
4
9
2
60kHz
2
2
2
0
2
100kHz
2
0
2
7
0
500kHz
1
7
9
0
0
1MHz
1
0
0
0
0
In general, it is possible to set various frequency adjustments and different positions for the
Slide switches (see point 4.2.). The data in this table are just recommendations for
orientation.
The most neutral and wide-band setting for LF-2 and LF-6 antennas can be achieved
by setting all the Control dial at postion 0 and both Slide switches at position 1. This
setting is recommended for measuring signals with unknown frequency and signals
higher than 500kHz.
Below graphic shows the typical resonance characteristics of the internal antennas
(particularly determined by the position of the Slide switches) of the MagnoTRACKER LF-2
and LF-6 antennas: