5 Year Warranty
Thank you for purchasing another quality Arrowhead Product.
We guarantee to replace or repair Arrowhead Manufactured product found to
be faulty due to defective materials or workmanship for
a period of 5 years from date of purchase.
The customer shall as soon as practicable after the discovery of any such defect or fault,
return the goods or defective parts thereof, to Arrowhead Alarm Products.
Freight to and from our stores is your care.
The company shall not be liable for any direct or consequential loss or damage attributed to the fault.
Nor shall the company be liable for any personal injury of any kind attributable to the fault.
The customer will keep the company indemnified against any such claim.
Any attempt by the customer to repair the goods with out written permission by the company could void the Warranty.
Page 7
New ESL Control Board
The ESL Control board is a combination of both Elite-S and Elite-S Lite Boards.
The new board has a completely new default configuration, making installation fast, smarter
and with less chance of error.
Hardware:
8 x Hardwired Zone Inputs
Still with the ability to Zone Double to 16
4 x Open Collector Outputs (Negative Switching)
1 x Relay Output (Clean 1A NO & NC Contacts)
3 x Individually Fused 12 Volt Outlets
All with Fuse Monitoring
Default Programming Configuration:
User Groups
Slots 1 to 39 are for standard Pin Code operation (original configuration)
Slots 40 to 49 are for Radio pendants desired to Arm only
Slots 50 to 59 are for Radio pendants desired to Disarm only
Slots 60 to 69 are for Radio pendants desired to Disarm and Activate Output 3
Slots 70 to 79 are for Radio pendants desired to Disarm and Activate Output 4
Slots 80 to 89 are for Radio pendants desired to Cause an Instant Panic
Slots 90 to 99 are configured for the TRX MAINS control
Slot 100 has been setup as a special Installer User Code location
Outputs
1 & 2 are as before for Internal and External Sirens, 300 second reset time
3 & 4 have been Linked for User and App control, 2 second reset time
5 to 8 are ready for User & App control and linked to KP, 5second reset time
Zones
1 to 8 are Hardwired Enabled zones, all Stay mode ready
9 to 16 are Wireless Enabled zones, all Stay mode ready
Keypads
1 & 2 both these keypads give entry delay beeps
3 to 8 have been linked to thier corresponding Output for access control
8 has also been setup for full App Control for Outputs 3 to 8 (as IP-Module = KP8)
Phone Numbers
1 to 4 these slots are for CID reporting (monitoring station or IP-Module/ESL APP KIT)
5 to 8 these slots are for Domestic reporting and only have 2 max. retry's set