AAON Orion ASM01824 Скачать руководство пользователя страница 4

CO

SENSOR

Technical Guide

 

4

Figure 2:  Wall Mounted Space CO

Sensor & Digital Room Sensor Wiring for VCM-X E-BUS Controller

Wall-Mounted Space CO

2

 Sensor Wiring to HVAC Unit Controller

Wall-Mounted CO

2

 Sensor

The Wall-Mounted Space CO

Sensor utilizes a sub-base mounting plate 

with a modular phone jack providing quick and easy mounting and wir-
ing. The wall-mounted sensor’s sub-base is compatible with standard 
junction boxes. A locking screw secures the assembly to the wall. 

Optional Mounting Plate

Included  with  the  CO

Sensor  is  a  mounting  plate  that  can  be 

used,  if  necessary,  to  cover  the  sensor  sheet  rock  opening.  This 
mounting  plate  screws  onto  the  back  of  the  housing  base.  The 
mounting  plate  is  then  mounted  and  covers  the  recessed  space 
in  the  wall.   A  locking  screw  secures  the  sensor  to  the  wall.  See 

Figure 8, page 10

 for mounting plate dimensions.

Wiring to the HVAC Unit Controller

The Wall-Mounted Space CO

Sensor connects to the VCM-X E-BUS 

Controller with the TSDRSC modular cable. It can be daisy-chained 

with the Digital Room Sensor or used separately from a Standard Room 
Temperature Sensor for applications requiring both a room CO

sensor 

and room temperature sensor. 

Refer to 

Figure 2

 for instructions.

Содержание Orion ASM01824

Страница 1: ...I2 C CO2 Sensor Technical Guide ...

Страница 2: ...18 382 6450 Controls Support Phone 866 918 1100 AAON P N G042470 Rev 01F Copyright August 2019 AAON Inc AAON is a registered trademark ofAAON Inc Tulsa OK AAON assumes no responsibility for errors or omissions This document is subject to change without notice PART NUMBER TABLE PART DESCRIPTION AAON P N Wall Mounted I2 C CO2 Space Sensor ASM01824 Duct Mounted I2 C CO2 Sensor RA or SA ASM01826 I2 C ...

Страница 3: ... box to sample the CO2 level in the duct Some typical applications are Controlling ventilation in a building where the occupancy varies frequently Controlling ventilation to ensure excess outdoor air is not causing energy waste Ensuring good air distribution throughout building zones Demand Control Ventilation Sensor Overview Features The CO2 Sensor provides the following Uses the patented dual be...

Страница 4: ... with the CO2 Sensor is a mounting plate that can be used if necessary to cover the sensor sheet rock opening This mounting plate screws onto the back of the housing base The mounting plate is then mounted and covers the recessed space in the wall A locking screw secures the sensor to the wall See Figure 8 page 10 for mounting plate dimensions Wiring to the HVAC Unit Controller The Wall Mounted Sp...

Страница 5: ...sensing the current CO2 level in the HVAC unit s return air stream The return air sensing use of this sensor is applied when you want an average CO2 reading in the area served by the HVAC unit or when you don t want a wall mounted CO2 Sensor due to sensor tampering concerns in the space The OE256 02 Duct Mounted CO2 Sensor is designed to be mounted in the return air duct of the HVAC unit and uses ...

Страница 6: ...ale cable connector s and cable s through the cable clamp opening and into the Aspiration Box using the appropriate length of pre fabricated TSDRSC cable s as required by your applica tion STEP 3 Remove the CO2 Sensor cover with circuit board by using the included Allen wrench to loosen the set screw located at the bottom edge of the CO2 Sensor assembly and pulling the Sensor cover with circuit bo...

Страница 7: ...Technical Guide CO2 SENSOR 7 Figure 5 Mounting and Cable Installation for Duct Mounted CO2 Sensor Duct Mounted CO2 Sensor Installation ...

Страница 8: ...ll be saved after loss of power Using LEDs to Troubleshoot LEDs are available for troubleshooting the CO2 Sensor The Front LED is visible through the front cover of the CO2 Sensor See Figure 7 for location The other LEDs are located on the Sensor s board and are only visible by removing the back cover See Figure 6 for locations LED ON OFF Push Button This button is located on the CO2 Sensor s boar...

Страница 9: ... and the sensor and controller are powered up Directions Set the meter for DC volts and connect the GND probe to the GND terminal and the probe to the CO2 0 5 terminal Look at the output voltage and record it Multiply the voltage times 400 The value should match the CO2 as read on the System Manager TS Modular System Manager Modular Service Tool or Prism If the signal doesn t match the sensor read...

Страница 10: ...he sensor sheet rock opening This mounting plate screws onto the back of the housing base The mounting plate is then mounted and covers the recessed space in the wall A locking screw secures the sensor to the wall See Figure 8 below for dimensions 1 638 1 810 0 882 1 407 1 842 0 733 2 110 2 920 0 810 R0 220 3 275 0 060 0 160 5 037 3 278 3 766 4 153 Figure 8 Mounting Plate Dimensions ...

Страница 11: ...Technical Guide CO2 SENSOR 11 Notes ...

Страница 12: ...ts Reserved AAON Factory Technical Support 918 382 6450 techsupport aaon com AAON Controls Support 866 918 1100 Monday through Friday 7 00 AM to 5 00 PM central standard time NOTE Before calling Technical Support please have the model and serial number of the unit available PARTS For replacement parts please contact your local AAON Representative ...

Отзывы: