background image

 

English  4

 

 

Symbols 

 

Symbols 

Function / Meaning 

Recommended Action 

 

Standby and Turn the device on. 

 

 

 

Battery installation guide 

 

 

 

Direct current 

 

 

SN 

Serial number 

 

 

 

Date of manufacture 

 

 

 

Type BF: Device, cuff and tubing are 
designed to provide special protection 
against electrical shocks. 

 

 

 

The indicator while measurement is in 
progress. It blinks while detecting the 
pulse. 

Measurement is in 
progress. Remain as still 
as possible. 

 

I

rregular 

H

eart

b

eat indicator. (I.H.B.) 

The indicator that detects irregular 
heartbeats or any excessive body 
movement during the measurement. 

 

 

 

Previous measurements stored in 
MEMORY. 

 

 

   Full Battery

 

The battery power indicator during 
measurement.  

 

 

  Low Battery

 

The battery is low when it blinks. 

Replace all batteries with 
new ones, when the 
indicator blinks. 

Unstable blood pressure due to 
movement during the measurement. 

Try measurement again. 
Remain very still during 
the measurement. 

The systolic and diastolic values are 
within 10 mmHg of each other. 

 

The pressure value did not increase 
during inflation. 

 

The cuff is not fastened correctly. 

 

PUL. DISPLAY ERROR 

The pulse is not detected correctly. 

Fasten the cuff correctly, 
and try the measurement 
again. 

SYS 

Systolic blood pressure in mmHg 

 

 

DIA 

Diastolic blood pressure in mmHg 

 

 

PUL./min 

Pulse per minute 

 

 

 

CLOCK button mark 

 

Alarm ON/OFF mark of the reminder 

If you want to stop the sound, 
press the START button. 

 

EC directive medical device label 

 

 

 

WEEE label

 

 

 

 

 

Содержание UA-787 Plus

Страница 1: ...Digital Blood Pressure Monitor Model UA 787 Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni Bedienungsanleitung WM PD4001187C...

Страница 2: ...ark On The Display 8 Attaching The Arm Cuff 8 How To Take Proper Measurements 8 Measurement 8 After Measurement 8 Measurements 9 Normal Measurement 9 Measurement With The Desired Systolic Pressure 10...

Страница 3: ...r use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be avoided Clean...

Страница 4: ...tton Air Hose Arm Cuff DC Jack START Button Orange illumination Air Connector Plug Air Socket MEMORY Button Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Systolic Pres...

Страница 5: ...ery The battery power indicator during measurement LowBattery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement du...

Страница 6: ...o page 11 Press the MEMORY button to recall the data The date and the most recent data are displayed The device can store the last sixty sets of data in memory automatically 3 Clearing Data Refer to p...

Страница 7: ...s Do not mix old and new batteries It may shorten the battery life or cause the device to malfunction LOW BATTERY mark does not appear when the batteries are drained Battery life varies with the ambie...

Страница 8: ...e current day and move to hour minute selection 5 Select the hour using the START button Press the CLOCK button to set the current hour and move to minute selection 6 Select the minute using the START...

Страница 9: ...ure measurement Sit comfortably at a table Rest your arm on the table Relax for about five to ten minutes before measurement Place the center of the cuff at the same height as your heart Remain still...

Страница 10: ...n Note If you wish to stop inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and heart mark blinks indicating that the measurement is in pr...

Страница 11: ...ited or depressed by emotional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An indiv...

Страница 12: ...ess the MEMORY button 2 The date and the most recent data are displayed 3 When the MEMORY button is pressed while data is displayed the previous data is displayed 4 After the last data is displayed th...

Страница 13: ...ring measurements Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classif...

Страница 14: ...regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 2...

Страница 15: ...etely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measurement Make sure you remain ve...

Страница 16: ...aintenance Technical Data Type UA 787 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 200 beats minute Measurement accuracy Pressure 3 mmHg or 2 whichever...

Страница 17: ......

Отзывы: